Temporal regularization in fully 5D reconstruction of cardiac gated dynamic SPECT images

Recently we developed two image reconstruction approaches aimed to unify gated imaging and dynamic imaging in nuclear cardiac imaging, the goal being to obtain an image sequence from a single acquisition which shows both cardiac motion and tracer distribution change over the course of imaging. While both approaches exploit the similarity among the different cardiac gate intervals, they differ in the form of temporal regularization imposed during reconstruction. In this work, we provide a quantitative comparison of these two approaches in terms of reconstruction accuracy of the myocardium using several quantitative measures, including signal-to-noise ratio, time activity curves, and ability for perfusion defect detection. In our experiments, we simulated gated cardiac imaging with the NURBS-based cardiac-torso phantom and Tc99m-Teboroxime as the imaging agent. The results show that both approaches could yield similar overall accuracy in the myocardium, and the B-spline approach could achieve slightly better estimation of the time activities compared to the dynamic EM approach.

[1]  William Paul Segars,et al.  Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom , 2001 .

[2]  Troy Farncombe,et al.  Functional dynamic spect imaging using a single slow camera rotation , 2000 .

[3]  L. Johnson,et al.  Myocardial perfusion imaging with technetium-99m-teboroxime. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  G T Gullberg,et al.  Effects of temporal modeling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[5]  Yongyi Yang,et al.  Tomographic Reconstruction of Dynamic Cardiac Image Sequences , 2007, IEEE Transactions on Image Processing.

[6]  S. Port Imaging guidelines for nuclear cardiology procedures , 1999 .

[7]  A. Celler,et al.  Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime , 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[8]  C. R. Deboor,et al.  A practical guide to splines , 1978 .

[9]  R. Huesman,et al.  Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections , 2002 .

[10]  O Muzik,et al.  The relationship between myocardial retention of technetium-99m teboroxime and myocardial blood flow. , 1992, Journal of the American College of Cardiology.

[11]  Richard M. Leahy,et al.  Spatiotemporal reconstruction of list-mode PET data , 2002, IEEE Transactions on Medical Imaging.

[12]  Yongyi Yang,et al.  Detectability of perfusion defect in gated dynamic cardiac SPECT images , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[13]  Jeffrey A. Fessler,et al.  Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms , 2003, IEEE Transactions on Medical Imaging.

[14]  E. Ficaro Imaging Guidelines for Nuclear Cardiology Procedures , 2006 .

[15]  Mingwu Jin,et al.  Fast dynamic image reconstruction for gated cardiac SPECT , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[16]  Carl de Boor,et al.  A Practical Guide to Splines , 1978, Applied Mathematical Sciences.

[17]  M. King,et al.  Reconstruction of dynamic gated cardiac SPECT. , 2006 .