Novel Microneedle Patches for Active Insulin Delivery are Efficient in Maintaining Glycaemic Control: An Initial Comparison with Subcutaneous Administration

PurposeGood glycaemic control is essential to minimize the risk for diabetes-induced complications. Also, compliance is likely to be higher if the procedure is simple and painless. This study was designed to validate painless intradermal delivery via a patch-like microneedle array.Materials and MethodsDiabetes was induced by an intravenous injection of streptozotocin (50 mg/kg bw) in adult male Sprague Dawley rats. Plasma insulin and blood glucose were measured before, during and after subcutaneous or intradermal (microneedles) infusion of insulin (0.2 IU/h) under Inactin-anaesthesia.ResultsBefore insulin administration, all animals displayed a pronounced hyperglycaemia (19 ± 1 mM; 359 mg/dl). Administration of insulin resulted in a reduced plasma glucose independently of administration route (subcutaneous 7.5 ± 4.2, n = 9, and intradermal 11 ± 1.8, n = 9 after 240 min), but with less errors of the mean in the intradermal group. In the intradermal group, plasma insulin was increased in all latter measurements (72 ± 22, 81 ± 34, and 87 ± 20 μIU/ml), as compared to the first measurement (26 ± 13). In the subcutaneous group, plasma insulin was elevated during the last measurement (to 154 ± 3.5 μIU/ml from 21 ± 18).ConclusionThis study presents a novel possibility of insulin delivery that is controllable and requires minimal training. This treatment strategy could improve compliance, and thus be beneficial for patients’ glycaemic control.

[1]  Diane E. Sutter,et al.  Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery , 2002, Nature Medicine.

[2]  G. Stemme,et al.  Reliable in-vivo penetration and transdermal injection using ultra-sharp hollow microneedles , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[3]  R. Szeimies,et al.  Hautveränderungen bei Diabetes mellitus , 2004, Der Hautarzt.

[4]  Göran Stemme,et al.  Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer , 2003 .

[5]  N. Roxhed,et al.  Compact, Seamless Integration of Active Dosing and Actuation with Microneedles for Transdermal Drug Delivery , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.

[6]  Robert C. Wolpert,et al.  A Review of the , 1985 .

[7]  M. Cormier,et al.  Transdermal Delivery of Antisense Oligonucleotides with Microprojection Patch (macroflux®) Technology , 2001, Pharmaceutical Research.

[8]  M. Allen,et al.  Lack of Pain Associated with Microfabricated Microneedles , 2001, Anesthesia and analgesia.

[9]  Mahmoud Ameri,et al.  Transdermal delivery of desmopressin using a coated microneedle array patch system. , 2004, Journal of controlled release : official journal of the Controlled Release Society.

[10]  A. Renold,et al.  Diabetogenic action of streptozotocin: relationship of dose to metabolic response. , 1969, The Journal of clinical investigation.

[11]  Sion A. Coulman,et al.  Minimally invasive cutaneous delivery of macromolecules and plasmid DNA via microneedles. , 2006, Current drug delivery.

[12]  Mark G. Allen,et al.  Hollow metal microneedles for insulin delivery to diabetic rats , 2005, IEEE Transactions on Biomedical Engineering.

[13]  Dorian Liepmann,et al.  Clinical microneedle injection of methyl nicotinate: stratum corneum penetration , 2005, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[14]  Mark R Prausnitz,et al.  Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force. , 2004, Journal of biomechanics.

[15]  S. D. Collins,et al.  Microneedle array for transdermal biological fluid extraction and in situ analysis , 2004 .

[16]  S. Dinh,et al.  Response of the lung to pulmonary insulin dosing in the rat model and effects of changes in formulation. , 2005, Diabetes technology & therapeutics.

[17]  M. Stumvoll,et al.  [Skin changes in diabetes mellitus]. , 2004, Der Hautarzt; Zeitschrift fur Dermatologie, Venerologie, und verwandte Gebiete.

[18]  Mark G. Allen,et al.  Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[19]  Melissa Ai Ling Teo,et al.  In Vitro and In Vivo Characterization of MEMS Microneedles , 2005, Biomedical microdevices.

[20]  Wijaya Martanto,et al.  Microinfusion Using Hollow Microneedles , 2006, Pharmaceutical Research.

[21]  M. Prausnitz Overcoming skin's barrier: the search for effective and user-friendly drug delivery. , 2001, Diabetes technology & therapeutics.

[22]  Wijaya Martanto,et al.  Transdermal Delivery of Insulin Using Microneedles in Vivo , 2004, Pharmaceutical Research.

[23]  T. Mandal,et al.  Inhaled insulin for diabetes mellitus. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[24]  A. Tiengo,et al.  The contribution of hyperglycaemia and hypoinsulinaemia to the insulin resistance of streptozotocin-diabetic rats , 1992, Diabetologia.

[25]  R. Reed,et al.  Interstitial exclusion of albumin in rat dermis and subcutis in over- and dehydration. , 1989, The American journal of physiology.

[26]  N. Sulli,et al.  Long‐term benefits of continuous subcutaneous insulin infusion in children with Type 1 diabetes: a 4‐year follow‐up , 2006, Diabetic medicine : a journal of the British Diabetic Association.

[27]  Mark R Prausnitz,et al.  Precise microinjection into skin using hollow microneedles. , 2006, The Journal of investigative dermatology.

[28]  J. Matriano,et al.  Macroflux® Microprojection Array Patch Technology: A New and Efficient Approach for Intracutaneous Immunization , 2004, Pharmaceutical Research.

[29]  I. Simpson,et al.  A possible mechanism of insulin resistance in the rat adipose cell in streptozotocin-induced diabetes mellitus. Depletion of intracellular glucose transport systems. , 1981, The Journal of clinical investigation.

[30]  D. Howey,et al.  [Lys(B28), Pro(B29)]‐human insulin: Effect of injection time on postprandial glycemia , 1995, Clinical pharmacology and therapeutics.

[31]  A. Johansen,et al.  Cutis/subcutis thickness at insulin injection sites and localization of simulated insulin boluses in children with Type 1 diabetes mellitus: need for individualization of injection technique? , 1998, Diabetic medicine : a journal of the British Diabetic Association.

[32]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[33]  J. Berger,et al.  Decreased expression of the insulin-responsive glucose transporter in diabetes and fasting , 1989, Nature.

[34]  B. Zinman,et al.  Alternative routes of insulin delivery , 2003, Diabetic medicine : a journal of the British Diabetic Association.

[35]  H. Wiig,et al.  Effect of hydration on interstitial distribution of charged albumin in rat dermis in vitro , 2005, The Journal of physiology.

[36]  Wijaya Martanto,et al.  Mechanism of fluid infusion during microneedle insertion and retraction. , 2006, Journal of controlled release : official journal of the Controlled Release Society.

[37]  L. Niskanen,et al.  FlexPen: addressing issues of confidence and convenience in insulin delivery. , 2005, Clinical therapeutics.

[38]  Regina Luttge,et al.  Silicon micromachined hollow microneedles for transdermal liquid transport , 2003 .

[39]  M. Davies,et al.  The reality of glycaemic control in insulin treated diabetes: defining the clinical challenges , 2004, International Journal of Obesity.

[40]  M. Korytkowski,et al.  A multicenter, randomized, open-label, comparative, two-period crossover trial of preference, efficacy, and safety profiles of a prefilled, disposable pen and conventional vial/syringe for insulin injection in patients with type 1 or 2 diabetes mellitus. , 2003, Clinical therapeutics.

[41]  A. Barnett Exubera inhaled insulin: a review , 2004, International journal of clinical practice.

[42]  M. Madou Fundamentals of microfabrication , 1997 .

[43]  R. Heine Unlocking the opportunity of tight glycaemic control , 2005, Diabetes, obesity & metabolism.