Performance evaluation of a compliant magnetorheological piston actuator

Compliant actuation is an indispensable element for safe physical human robot interaction. However, there is a lack of devices, which can integrate the high power density of hydraulic actuators with intrinsically safe mechanisms. This drove the development a new type of hydraulic magneto-rheological piston. This device includes a novel toroidal array of magnetorheological valves in its head. In previous studies, the system performance was evaluated only as a traditional damping system. Now, the piston is connected to a pump to create a hydraulic compliant actuator. This novel compliant piston is capable to control the piston speed and force independently by using the pump and electromagnet voltages respectively. In this way, different combinations of these parameters can be used to achieve diverse system properties; e.g. low response time or energy efficiency. Several experiments are conducted to evaluate its performance, including force, friction, speed, and step response. The results display the potential of the devices to be used as an active system for compliant hydraulic robotic applications. They also hint to the possibilities to improve by using a more sophisticated control system for its speed and force.

[1]  Clément Gosselin,et al.  Series Clutch Actuators for safe physical human-robot interaction , 2011, 2011 IEEE International Conference on Robotics and Automation.

[2]  Shigeki Sugano,et al.  An iterative design methodology for the performance optimisation of magnetorheological piston head configurations , 2016, 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM).

[3]  Jin-Hyeong Yoo,et al.  Performance of a Magnetorheological Hydraulic Power Actuation System , 2004 .

[4]  Pavel Kuzhir,et al.  Effect of the orientation of the magnetic field on the flow of a magnetorheological fluid. I. Plane channel , 2003 .

[5]  Alin Albu-Schäffer,et al.  Dynamic modelling and control of variable stiffness actuators , 2010, 2010 IEEE International Conference on Robotics and Automation.

[6]  Masayuki Inaba,et al.  Design of powerful and flexible musculoskeletal arm by using nonlinear spring unit and electromagnetic clutch opening mechanism , 2011, 2011 11th IEEE-RAS International Conference on Humanoid Robots.

[7]  Shigeki Sugano,et al.  Development of a backdrivable magnetorheological hydraulic piston for passive and active linear actuation , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[8]  Yan Peng,et al.  Hybrid position, posture, force and moment control with impedance characteristics for robot manipulators , 2011, 2011 IEEE International Conference on Mechatronics and Automation.

[9]  Gen Endo,et al.  Development of a light duty arm with an active-fingertip gripper for handling discoid objects , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  Günter Niemeyer,et al.  Variable impedance magnetorheological Clutch Actuator and telerobotic implementation , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[11]  Seung-Bok Choi,et al.  Design and novel type of a magnetorheological damper featuring piston bypass hole , 2015 .

[12]  Qiong Liu,et al.  A design methodology for a magnetorheological fluid damper based on a multi-stage radial flow mode , 2012 .

[13]  Hiroshi Kaminaga,et al.  Development of high-power and backdrivable linear electro-hydrostatic actuator , 2014, 2014 IEEE-RAS International Conference on Humanoid Robots.