Self-commissioning notch filter for active damping in three phase LCL-filter based grid converters

LCL-filters are used to mitigate the harmonic current content in grid converters. The LCL-filter resonance must be damped in order to avoid stability problems in the current control. Active damping avoids resistors at the expense of increased control complexity. Large grid impedance variations can challenge the LCL-filter stability. Active damping by using a notch filter on the reference voltage for the modulator is simple to implement and does not require additional sensors. With the notch frequency tuned for the resonant frequency the voltage reference does not contain any component susceptible of exciting the LCL-filter. However, the notch filter tuning requires considerable design effort and the variations in the resonance frequency limit the LCL-filter robustness. This paper proposes a simple tuning procedure for the notch filter that results in proper robustness. In order to cope with the grid inductance variations it is proposed to estimate the resonance frequency by means of Fourier analysis. The Goertzel algorithm, instead of the FFT, is used to reduce the calculation and memory requirements. Thus, the proposed self-commissioning notch filter results robust and consumes little computational resources. Finally, the analysis is validated with both simulation and experiments.

[1]  Pavel Rajmic,et al.  Goertzel algorithm generalized to non-integer multiples of fundamental frequency , 2012, EURASIP J. Adv. Signal Process..

[2]  Frede Blaabjerg,et al.  Generalized Design of High Performance Shunt Active Power Filter With Output LCL Filter , 2012, IEEE Transactions on Industrial Electronics.

[3]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[4]  M. Liserre,et al.  Grid Impedance Estimation via Excitation of $LCL$ -Filter Resonance , 2007, IEEE Transactions on Industry Applications.

[5]  M. Liserre,et al.  Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters , 2013, IEEE Transactions on Power Electronics.

[6]  M. Liserre,et al.  Stability improvements of an LCL-filter based three-phase active rectifier , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[7]  M. Liserre,et al.  Stability of grid-connected PV inverters with large grid impedance variation , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[8]  Marco Liserre,et al.  Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters , 2014, IEEE Transactions on Industrial Informatics.

[9]  Mariusz Malinowski,et al.  A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter , 2008, IEEE Transactions on Industrial Electronics.

[10]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[11]  Ahmet M. Hava,et al.  Utility interface issues for line connected PWM voltage source converters: a comparative study , 1995, Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95.

[12]  Alan V. Oppenheim,et al.  Discrete-time signal processing (2nd ed.) , 1999 .

[13]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[14]  Frede Blaabjerg,et al.  Step-by-step design procedure for a grid-connected three-phase PWM voltage source converter , 2004 .

[15]  Sen M. Kuo,et al.  Real-time digital signal processing , 2001 .

[16]  M. Liserre,et al.  Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.

[17]  Pekik Argo Dahono A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[18]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.