Computer-aided stream pollution control and management. Part II
暂无分享,去创建一个
The dissolved oxygen drop is a function of the combined biochemical oxygen demand loads of upstream, the temperature of stream water and the stream flow. A mathematical model which adequately expresses this function can be developed by means of the multiple linear correlation method. The methods and the procedures used for mathematical modelling are described. Practical examples are presented and discussed.