Telemetric system for monitoring of endoleak in abdominal aorta aneurysm using multiple pressure sensors integrated on a stent graft

An abdominal aortic aneurysm (AAA) is the dilation of the abdominal aorta due to weakening of the arterial wall. Endovascular aneurysm repair (EVAR) using an implantable stent graft is the commonly used method for treatment of AAA. An endoleak, which is the leakage of blood around the stent graft, is the complication after EVAR creating trauma to the weakened arterial walls of the aneurysm leading to further enlargement and risk of rupture. This paper details the design, implementation and testing of a wirelessly powered implant device containing multiple pressure sensors to be mounted on a stent graft for detecting endoleak. The tested implant device can be powered for distance of 20 cm using an external RF power source of 2.65 W. A stent prototype with sixteen pressure sensors is fabricated and tested using an in-vitro chamber. The resolution and directionality of the pressure sensors in the stent prototype are measured. Different wire bonding glob top encapsulations are evaluated for mechanical stress induced during stent delivery.

[1]  Dietmar Schroeder,et al.  Wireless Energy and Data Transmission ASIC for Blood Pressure Measurement in an Aneurysm Implant , 2016, BIODEVICES.

[2]  Wolfgang Krautschneider,et al.  Wireless Power and Data Transmission for a Pressure Sensing Medical Implant , 2010 .

[3]  Gerhard Adam,et al.  Wireless blood pressure measurement implant electronics for integration in a stent craft , 2016 .

[4]  RFID implantable pressure sensor for the follow-up of abdominal aortic aneurysm stented , 2011, 2011 6th International Conference on Design & Technology of Integrated Systems in Nanoscale Era (DTIS).

[5]  L. Ayiku,et al.  Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm , 2005, The British journal of surgery.

[6]  D. Ballard,et al.  Abdominal Aortic Aneurysm (Aaa): Cost-Effectiveness of Screening, Surveillance of Intermediate-Sized Aaa, and Management of Symptomatic Aaa , 2005, Proceedings.

[7]  M. Addis,et al.  First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. , 2004, Journal of vascular surgery.

[8]  Joseph A Potkay,et al.  Long term, implantable blood pressure monitoring systems , 2008, Biomedical microdevices.

[9]  Ritwick Raj Bhuyan,et al.  Outcomes of surgical management of ruptured abdominal aortic aneurysm , 2006 .

[10]  Thomas Schmitz-Rode,et al.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study , 2007, European Radiology.

[11]  M. Allen,et al.  Micromachined endovascularly-implantable wireless aneurysm pressure sensors: from concept to clinic , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..