Anterior cruciate reconstruction using a Dacron ligament prosthesis

A single-center prospective study is presented on 35 patients who underwent anterior cruciate ligament re construction using a Dacron ligament prosthesis. All of the reconstructions were performed by the same sur geon, using the same technique. All of the patients had a history of symptomatic chronic ACL insufficiency. The mean follow-up interval for all patients was 50 months. There was an overall failure rate of 37.1% (13 patients), based on the presence of at least one of the following criteria: the presence of a pivot shift; a 2+ or greater anterior drawer or Lachman; instrumented laxity of >3 mm side-to-side translation in 20° of flexion at 89 N; or by arthroscopic documentation. Six of these 13 patients were documented by arthroscopy and 7 were clinical failures. There were 26 patients with only anterior cruciate ligament laxity, and 9 patients with multiple instabilities or failed previous ACL reconstruction ("salvage"). In the group with isolated anterior cruciate ligament insuffi ciency, the failure rate was 23% (6 patients). In the salvage group, the failure rate was 78% (7 patients). There was a significant improvement in patient perform ance with respect to clinical laxity, Lysholm scores, and Tegner activity levels at 2 years postoperatively. There has been a subsequent deterioration in the performance of these patients through time.

[1]  D. Dandy,et al.  Reconstruction for chronic anterior cruciate instability. A comparison of two methods after six years. , 1988, The Journal of bone and joint surgery. British volume.

[2]  R. Gidumal Combined anterior cruciate-ligament reconstruction using semitendinosus tendon and iliotibial tract. , 1986, The Journal of bone and joint surgery. American volume.

[3]  T. Wickiewicz,et al.  Long-term followup of anterior cruciate ligament reconstruction using the quadriceps tendon substitution for chronic anterior cruciate ligament insufficiency , 1988, The American journal of sports medicine.

[4]  P. Indelicato,et al.  Early experience with the GORE-TEX polytetrafluoroethylene anterior cruciate ligament prosthesis , 1989, The American journal of sports medicine.

[5]  J. Lysholm,et al.  Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale , 1982, The American journal of sports medicine.

[6]  K. Dehaven,et al.  An anterior cruciate ligament (ACL) evaluation format for assessment of artificial or autologous anterior cruciate reconstruction results. , 1987, Clinical orthopaedics and related research.

[7]  R. L. Larson,et al.  Anterior cruciate reconstruction in the chronically unstable knee using an expanded polytetrafluoroethylene (PTFE) prosthetic ligament , 1987, The American journal of sports medicine.

[8]  J. Richmond,et al.  A multicenter study on the results of anterior cruciate ligament reconstruction using a Dacron ligament prosthesis in "salvage" cases , 1989, The American journal of sports medicine.

[9]  J. Lysholm,et al.  Rating systems in the evaluation of knee ligament injuries. , 1985, Clinical orthopaedics and related research.