Comparison of Wearable and Clinical Devices for Acquisition of Peripheral Nervous System Signals

A key access point to the functioning of the autonomic nervous system is the investigation of peripheral signals. Wearable devices (WDs) enable the acquisition and quantification of peripheral signals in a wide range of contexts, from personal uses to scientific research. WDs have lower costs and higher portability than medical-grade devices. However, the achievable data quality can be lower, and data are subject to artifacts due to body movements and data losses. It is therefore crucial to evaluate the reliability and validity of WDs before their use in research. In this study, we introduce a data analysis procedure for the assessment of WDs for multivariate physiological signals. The quality of cardiac and electrodermal activity signals is validated with a standard set of signal quality indicators. The pipeline is available as a collection of open source Python scripts based on the pyphysio package. We apply the indicators for the analysis of signal quality on data simultaneously recorded from a clinical-grade device and two WDs. The dataset provides signals of six different physiological measures collected from 18 subjects with WDs. This study indicates the need to validate the use of WDs in experimental settings for research and the importance of both technological and signal processing aspects to obtain reliable signals and reproducible results.

[1]  Kristof Van Laerhoven,et al.  Wearable-Based Affect Recognition—A Review , 2019, Sensors.

[2]  Mohammad Soleymani,et al.  A Multimodal Database for Affect Recognition and Implicit Tagging , 2012, IEEE Transactions on Affective Computing.

[3]  J. Vagedes,et al.  How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram. , 2013, International journal of cardiology.

[4]  M. Nock,et al.  Using Wearable Physiological Monitors With Suicidal Adolescent Inpatients: Feasibility and Acceptability Study , 2019, JMIR mHealth and uHealth.

[5]  R. Levenson The Autonomic Nervous System and Emotion , 2014 .

[6]  Y. Koumpouros,et al.  Wearables and mobile technologies in Autism Spectrum Disorder interventions: A systematic literature review , 2019, Research in Autism Spectrum Disorders.

[7]  Ki H. Chon,et al.  Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph , 2016, Sensors.

[8]  V. Somers,et al.  Heart Rate Variability: , 2003, Journal of cardiovascular electrophysiology.

[9]  Matthew S. Goodwin,et al.  Atypical Emotional Electrodermal Activity in Toddlers with Autism Spectrum Disorder , 2020, Autism research : official journal of the International Society for Autism Research.

[10]  Melanie Swan,et al.  Sensor Mania! The Internet of Things, Wearable Computing, Objective Metrics, and the Quantified Self 2.0 , 2012, J. Sens. Actuator Networks.

[11]  Kirk H. Shelley,et al.  Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Nam-Trung Nguyen,et al.  Stretchable respiration sensors: Advanced designs and multifunctional platforms for wearable physiological monitoring. , 2020, Biosensors & bioelectronics.

[13]  Cesare Furlanello,et al.  pyphysio: A physiological signal processing library for data science approaches in physiology , 2019, SoftwareX.

[14]  Cesare Furlanello,et al.  DBD-RCO: Derivative Based Detection and Reverse Combinatorial Optimization to improve heart beat detection for wearable devices , 2017, bioRxiv.

[15]  Ming-Zher Poh,et al.  Wearable sensors: Opportunities and challenges for low-cost health care , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[16]  Jennifer Healey,et al.  Toward Machine Emotional Intelligence: Analysis of Affective Physiological State , 2001, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  David R Bassett,et al.  Device-based monitoring in physical activity and public health research , 2012, Physiological measurement.

[18]  R G Mark,et al.  Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter , 2008, Physiological measurement.

[19]  The wrist is not the brain: Estimation of sleep by clinical and consumer wearable actigraphy devices is impacted by multiple patient‐ and device‐specific factors , 2020, Journal of sleep research.

[20]  Joseph Wang,et al.  Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring. , 2014, Biosensors & bioelectronics.

[21]  Jae‐Woong Jeong,et al.  Advanced Soft Materials, Sensor Integrations, and Applications of Wearable Flexible Hybrid Electronics in Healthcare, Energy, and Environment , 2019, Advanced materials.

[22]  Anne-Marie Brouwer,et al.  A Usability Study of Physiological Measurement in School Using Wearable Sensors , 2020, Sensors.

[23]  M. Bornstein,et al.  Strangers, Friends, and Lovers Show Different Physiological Synchrony in Different Emotional States , 2019, Behavioral sciences.

[24]  Nicola Cellini,et al.  Wearable Sleep Technology in Clinical and Research Settings , 2019, Medicine and science in sports and exercise.

[25]  Victoria Xia,et al.  Active learning for electrodermal activity classification , 2015, 2015 IEEE Signal Processing in Medicine and Biology Symposium (SPMB).

[26]  Zhenan Bao,et al.  Electronic Skin: Recent Progress and Future Prospects for Skin‐Attachable Devices for Health Monitoring, Robotics, and Prosthetics , 2019, Advanced materials.

[27]  John M. Graybeal,et al.  The Effect of Motion on Pulse Oximetry and Its Clinical Significance , 2007, Anesthesia and analgesia.

[28]  Maja Pantic,et al.  This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. IEEE TRANSACTIONS ON AFFECTIVE COMPUTING , 2022 .

[29]  S. R. Yadhuraj,et al.  Motion Artifact Reduction in Photoplethysmographic Signals: A Review , 2013 .

[30]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[31]  Murat Akcakaya,et al.  Simple, Transparent, and Flexible Automated Quality Assessment Procedures for Ambulatory Electrodermal Activity Data , 2018, IEEE Transactions on Biomedical Engineering.

[32]  Qiao Li,et al.  ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction , 2013, IEEE Transactions on Biomedical Engineering.

[33]  Anne-Marie Brouwer,et al.  A Comparison between Laboratory and Wearable Sensors in the Context of Physiological Synchrony , 2020, ICMI.

[34]  Mohamed Elgendi,et al.  Optimal Signal Quality Index for Photoplethysmogram Signals , 2016, Bioengineering.

[35]  Maria Lindén,et al.  A Systematic Review of Wearable Patient Monitoring Systems – Current Challenges and Opportunities for Clinical Adoption , 2017, Journal of Medical Systems.

[36]  M. Malik Heart Rate Variability , 1996, Clinical cardiology.

[37]  Jeremiah D. Wander,et al.  A combined segmenting and non-segmenting approach to signal quality estimation for ambulatory photoplethysmography , 2014, Physiological measurement.

[38]  Rosalind W. Picard,et al.  Empatica E3 — A wearable wireless multi-sensor device for real-time computerized biofeedback and data acquisition , 2014, 2014 4th International Conference on Wireless Mobile Communication and Healthcare - Transforming Healthcare Through Innovations in Mobile and Wireless Technologies (MOBIHEALTH).

[39]  Jean-Yves Fourniols,et al.  Smart wearable systems: Current status and future challenges , 2012, Artif. Intell. Medicine.

[40]  Thierry Pun,et al.  DEAP: A Database for Emotion Analysis ;Using Physiological Signals , 2012, IEEE Transactions on Affective Computing.

[41]  H-S Philip Wong,et al.  Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care , 2014, Nature Communications.

[42]  Zhenan Bao,et al.  Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow , 2019, Nature Biomedical Engineering.

[43]  Joris H. Janssen,et al.  Emotional sweating across the body: Comparing 16 different skin conductance measurement locations , 2012, Physiology & Behavior.

[44]  R. van Hillegersberg,et al.  Vital Signs Monitoring with Wearable Sensors in High-risk Surgical Patients , 2019, Anesthesiology.

[45]  M. Bornstein,et al.  Physical presence of spouse enhances brain-to-brain synchrony in co-parenting couples , 2020, Scientific Reports.

[46]  Di Wang,et al.  Reliable Breathing Tracking With Wearable Mask Device , 2020, IEEE Sensors Journal.

[47]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[48]  Sylvia D. Kreibig,et al.  Autonomic nervous system activity in emotion: A review , 2010, Biological Psychology.

[49]  E. Gordon,et al.  Separating individual skin conductance responses in a short interstimulus-interval paradigm , 2005, Journal of Neuroscience Methods.

[50]  Akane Sano,et al.  Automatic identification of artifacts in electrodermal activity data , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[51]  Jean-Yves Reginster,et al.  The promise of wearable activity sensors to define patient recovery , 2014, Journal of Clinical Neuroscience.

[52]  Bor-Shyh Lin,et al.  Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors , 2014, Sensors.