Estimation of Cerebral Blood Flow Through Color Duplex Sonography of the Carotid and Vertebral Arteries in Healthy Adults

Background and Purpose To noninvasively estimate cerebral blood flow volume, a prospective study of color duplex sonography of the common, external, and internal carotid arteries and vertebral arteries of healthy adults was done. Cerebral blood flow was calculated with the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Methods Using a 7.0-MHz linear transducer of a computed sonography system, cervical arteries of 48 volunteers (23 women, 25 men; mean age, 35 ±12 years) were examined. We measured angle-corrected time-averaged velocities and the diameter of the vessels and calculated the flow volumes of all arteries. In addition, peak systolic, maximum end-diastolic, and time-averaged maximum velocities and the resistance, pulsatility, and spectral broadening indexes were determined. Furthermore, we analyzed the side-to-side difference, age dependence, and long-term reproducibility of these parameters. Results The mean±SD values of flow volumes in the common, internal, and external carotid and vertebral arteries were 470+120, 265±62,160±66, and 85±33 mL/min on either side, respectively. Total cerebral blood flow was 701 ±104 mL/min (corresponding to 54±8 mL/100 g per minute), with no variation in age or sex. Long-term reproducibility of cerebral blood flow and flow volumes in all vessels was significant (P < .01). Conclusions We conclude that color duplex sonography of cervical arteries is potentially a practical method for estimating total cerebral blood flow. This noninvasive technique may be ideally suited for bedside and follow-up examinations of the critically ill patient. In future studies it should be compared with established radionuclide techniques.

[1]  S. Kety,et al.  THE NITROUS OXIDE METHOD FOR THE QUANTITATIVE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN: THEORY, PROCEDURE AND NORMAL VALUES. , 1948, The Journal of clinical investigation.

[2]  H. Torp,et al.  Flow Estimation Using Ultrasound Imaging (Color M-Mode) and Computer Postprocessing , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[3]  S. Kety Human cerebral blood flow and oxygen consumption as related to aging. , 1956, Research publications - Association for Research in Nervous and Mental Disease.

[4]  M. Anliker,et al.  Noninvasive Measurement of Velocity Profiles and Blood Flow in the Common Carotid Artery by Pulsed Doppler Ultrasound , 1976, Stroke.

[5]  S. Uematsu,et al.  Measurement of carotid blood flow in man and its clinical application. , 1983, Stroke.

[6]  P. Hoskins,et al.  Measurement of arterial blood flow by Doppler ultrasound. , 1990, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  Richard S. J. Frackowiak,et al.  Cerebral blood flow, blood volume and oxygen utilization. Normal values and effect of age. , 1990, Brain : a journal of neurology.

[8]  P. Bendick,et al.  Hemodynamic evaluation of vertebral arteries by duplex ultrasound. , 1990, The Surgical clinics of North America.

[9]  V. Jackson,et al.  Evaluation of the vertebral arteries with duplex sonography. , 1986, Journal of vascular surgery.

[10]  S. Kety,et al.  THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS , 1945 .

[11]  R. Buchholz,et al.  Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adults. , 1993, Journal of neurosurgery.

[12]  T. Wada,et al.  Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings. , 1991, Stroke.

[13]  F. Sakai,et al.  Effects of advancing age on regional cerebral blood flow. Studies in normal subjects and subjects with risk factors for atherothrombotic stroke. , 1979, Archives of neurology.

[14]  D. Laplane,et al.  Duplex scanning of normal vertebral arteries. , 1986, Stroke.

[15]  N. Lassen,et al.  A single photon dynamic computer assisted tomograph (DCAT) for imaging brain function in multiple cross sections. , 1980, Journal of computer assisted tomography.

[16]  H. Smith Quantitative Doppler Flowmetry , 1984, Acta radiologica: diagnosis.

[17]  R. Gill Measurement of blood flow by ultrasound: accuracy and sources of error. , 1985, Ultrasound in medicine & biology.

[18]  B. Lévy,et al.  Evaluation of human hemispheric blood flow based on non invasive carotid blood flow measurements using the range-gated Doppler technique. , 1982, Stroke.

[19]  O. Paulson,et al.  99mTc-d,l-HMPAO and SPECT of the Brain in Normal Aging , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[20]  J V Straumfjord,et al.  Analysis of brain weight. I. Adult brain weight in relation to sex, race, and age. , 1980, Archives of pathology & laboratory medicine.

[21]  S M Davis,et al.  Cerebral blood flow and cerebrovascular CO2 reactivity in stroke‐age normal controls , 1983, Neurology.

[22]  J. Walter,et al.  Evaluation of the Vertebrobasilar–Posterior System by Transcranial Color Duplex Sonography in Adults , 1992, Stroke.

[23]  G. Niemann,et al.  Transcranial Color Duplex Sonography in Childhood and Adolescence: Age Dependence of Flow Velocities and Waveform Parameters , 1993, Stroke.

[24]  F Shishido,et al.  Reduction in regional cerebral metabolic rate of oxygen during human aging. , 1986, Stroke.

[25]  J. Fortune,et al.  Human cerebrovascular response to oxygen and carbon dioxide as determined by internal carotid artery duplex scanning. , 1991, The Journal of trauma.

[26]  J. Fortune,et al.  Duplex scanning of the internal carotid artery: An assessment of cerebral blood flow , 1987, The British journal of surgery.

[27]  H. R. Muller,et al.  Cranial blood flow measurement by means of Doppler ultrasound , 1987 .

[28]  H. Ehringer,et al.  [The extracranial carotid artery in a high-resolution real-time ultrasonic imaging system: the morphological findings in healthy young adults]. , 2008, Ultraschall in der Medizin.

[29]  O B Paulson,et al.  Regional Cerebral Blood Flow Assessed by 133Xe Inhalation and Emission Tomography: Normal Values , 1985, Journal of computer assisted tomography.

[30]  E. Hoffman,et al.  A positron-emission transaxial tomograph for nuclear imaging (PETT). , 1975, Radiology.

[31]  V. Zbornikova,et al.  Duplex scanning in presumably normal persons of different ages. , 1986, Ultrasound in medicine & biology.

[32]  S. Trattnig,et al.  Color-coded Doppler imaging of normal vertebral arteries. , 1990, Stroke.