The computation in diagnostics for tokamaks: systems, designs, approaches

The requirements given for GEM (Gaseous Electron Multiplier) detector based acquisition system for plasma impurities diagnostics triggered a need for the development of a specialized software and hardware architecture. The amount of computations with latency and throughput restrictions cause that an advanced solution is sought for. In order to provide a mechanism fitting the designated tokamaks, an insight into existing solutions was necessary. In the article there is discussed architecture of systems used for plasma diagnostics and in related scientific fields. The developed solution is compared and contrasted with other diagnostic and control systems. Particular attention is payed to specific requirements for plasma impurities diagnostics in tokamak thermal fusion reactor. Subsequently, the details are presented that justified the choice of the system architecture and the discussion on various approaches is given.

[1]  G. Kasprowicz,et al.  Data processing and analysis for 2D imaging GEM detector system , 2014, Other Conferences.

[2]  N Rath,et al.  Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units. , 2014, The Review of scientific instruments.

[3]  N. W. Eidietis,et al.  Designing, constructing and using Plasma Control System algorithms on DIII-D , 2013, 2013 IEEE 25th Symposium on Fusion Engineering (SOFE).

[4]  Krzysztof T. Pozniak,et al.  Introducing parallelism to histogramming functions for GEM systems , 2015, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[5]  R. Castro,et al.  A high throughput data acquisition and processing model for applications based on GPUs , 2015 .

[6]  Gerhard Raupp,et al.  Real-time signal communication between diagnostic and control in ASDEX Upgrade , 2010 .

[7]  F. Janky,et al.  Plasma density control in real-time on the COMPASS tokamak , 2015 .

[8]  Sejal Shah,et al.  Design of Data Acquisition and Control System for Indian Test Facility of Diagnostics Neutral Beam , 2015 .

[9]  Krzysztof T. Poźniak,et al.  On algorithmic optimization of histogramming functions for GEM systems , 2015, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[10]  G. Kasprowicz,et al.  On line separation of overlapped signals from multi-time photons for the GEM-based detection system , 2015, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[11]  D. Mazon,et al.  Design of soft-X-ray tomographic system in WEST using GEM detectors , 2015 .

[12]  CurrentDrive,et al.  Chapter?8: Plasma operation and control , 1999 .

[13]  V. Toigo,et al.  A substantial step forward in the realization of the ITER HNB system: The ITER NBI Test Facility , 2017 .

[14]  V Innocente,et al.  Evaluating the power efficiency and performance of multi-core platforms using HEP workloads , 2015 .

[15]  G. Ambrosino,et al.  Improving the performance of the JET Shape Controller , 2015 .

[16]  Max -‐ Planck Institute for Plasma Physics Architectural concept for the ITER Plasma Control System , .

[17]  Volker Lindenstruth,et al.  The ALICE High Level Trigger: status and plans , 2015 .

[18]  G. Manduchi,et al.  Integration of Simulink, MARTe and MDSplus for rapid development of real-time applications , 2015 .

[19]  Krzysztof T. Pozniak,et al.  The Speedup Analysis in GEM Detector Based Acquisition System Algorithms with CPU and PCIe Cards , 2016 .

[20]  D. Moreau,et al.  Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments. , 2012, The Review of scientific instruments.

[21]  Gerhard Raupp,et al.  ASDEX Upgrade CODAC overview , 2009 .

[22]  C. Taliercio,et al.  Architecture of SPIDER control and data acquisition system , 2012 .

[23]  Gerald A. Navratil,et al.  High-speed, multi-input, multi-output control using GPU processing in the HBT-EP tokamak , 2012 .

[24]  F. Belli,et al.  First results on runaway electron studies using the FTU neutron camera , 2015 .

[25]  G. Kasprowicz White Rabbit Timing Receiver for Micro TCA-based Data Acquisition Systems for Applications in High Energy Physics , 2016 .

[26]  A. V. Melnikov,et al.  Control and data acquisition for dual HIBP diagnostics in the TJ-II stellarator , 2015 .

[27]  Tomasz Czarski,et al.  Conceptual design and development of GEM based detecting system for tomographic tungsten focused transport monitoring , 2015 .

[28]  G. Kasprowicz,et al.  Automatization of hardware configuration for plasma diagnostic system , 2016, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[29]  Didier Mazon,et al.  As hot as it gets , 2016 .

[30]  C. Neri,et al.  Instrumentation, control and data acquisition system with multiple configurations for test in nuclear environment , 2015 .

[31]  Gerhard Raupp,et al.  Implementation strategy for the ITER plasma control system , 2015 .

[32]  Andrzej Nowak,et al.  Does the Intel Xeon Phi processor fit HEP workloads , 2014 .

[33]  G. Bruno,et al.  A New Boson with a Mass of 125 GeV Observed with the CMS Experiment at the Large Hadron Collider , 2012, Science.

[34]  Marcello Cinque,et al.  Towards a preliminary design of the ITER plasma control system architecture , 2017 .

[35]  Gerhard Raupp,et al.  ASDEX Upgrade Discharge Control System – A real-time plasma control framework , 2014 .

[36]  Andrzej Nowak,et al.  Beyond core count: a look at new mainstream computing platforms for HEP workloads , 2014 .

[37]  Krzysztof T. Poźniak,et al.  Algorithm for fast event parameters estimation on GEM acquired data , 2016, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[38]  Antonio Barbalace,et al.  MARTe: A Multiplatform Real-Time Framework , 2010, IEEE Transactions on Nuclear Science.

[39]  Olaf Neubauer,et al.  Diagnostic setup for investigation of plasma wall interactions at Wendelstein 7-X , 2015 .

[40]  Krzysztof T. Poźniak,et al.  The development of algorithms for the deployment of new version of GEM-detector-based acquisition system , 2016, Symposium on Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments (WILGA).

[41]  Krzysztof T. Pozniak,et al.  Serial data acquisition for GEM-2D detector , 2014, Other Conferences.