Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes.
暂无分享,去创建一个
Ronald J Triolo | Kenneth J Gustafson | R. Triolo | G. Pinault | John A. Davis | K. Gustafson | Gilles C J Pinault | Jennifer J Neville | Ishaq Syed | John A Davis | Jesse Jean-Claude | Ishaq Y. Syed | Jesse Jean-Claude
[1] W. Grill,et al. Quantification of recruitment properties of multiple contact cuff electrodes. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[2] J. Thomas Mortimer,et al. Recruitment properties of monopolar and bipolar epimysial electrodes , 2006, Annals of Biomedical Engineering.
[3] D. Durand,et al. Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.
[4] E. Marsolais,et al. Implanted Functional Neuromuscular Stimulation systems for individuals with cervical spinal cord injuries: clinical case reports. , 1996, Archives of physical medicine and rehabilitation.
[5] B. Arensburg,et al. Microsurgical anatomy of the facial nerve trunk , 2002, Clinical anatomy.
[6] P. H. Peckham,et al. An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients* , 1997, The Journal of bone and joint surgery. American volume.
[7] S SUNDERLAND,et al. The intraneural topography of the radial, median and ulnar nerves. , 1945, Brain : a journal of neurology.
[8] R. Triolo,et al. Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand? , 2001, Journal of rehabilitation research and development.
[9] Michael W. Keith,et al. A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system , 1994 .
[10] Michael E. Miller,et al. Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[11] K. L. Moore,et al. Clinically Oriented Anatomy , 1985 .
[12] R J Triolo,et al. Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[13] M. Schiefer,et al. Fascicular Perineurium Thickness, Size, and Position Affect Model Predictions of Neural Excitation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[14] R Kobetic,et al. Effects of stimulated hip extension moment and position on upper-limb support forces during FNS-induced standing--a technical note. , 2001, Journal of rehabilitation research and development.
[15] R. Triolo,et al. A Model of Selective Activation of the Femoral Nerve With a Flat Interface Nerve Electrode for a Lower Extremity Neuroprosthesis , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[16] E. Marsolais,et al. Implantation of a 16‐Channel Functional Electrical Stimulation Walking System , 1998, Clinical orthopaedics and related research.
[17] J. Mortimer,et al. Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[18] N Bhadra,et al. Surgical technique for installing an eight-channel neuroprosthesis for standing. , 2001, Clinical orthopaedics and related research.
[19] Warren M. Grill,et al. Fascicular anatomy and surgical access of the human pudendal nerve , 2005, World Journal of Urology.
[20] R Kobetic,et al. The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[21] D. Durand,et al. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[22] J T Mortimer,et al. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. , 2000, Journal of biomedical materials research.
[23] E. Marsolais,et al. Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[24] Dominique M. Durand,et al. Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis , 2001, IEEE Transactions on Biomedical Engineering.
[25] P H Peckham,et al. Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[26] G. Obinata,et al. Restoration and analysis of standing-up in complete paraplegia utilizing functional electrical stimulation. , 1995, Archives of physical medicine and rehabilitation.
[27] M E Jabaley,et al. Internal topography of major nerves of the forearm and hand: a current view. , 1980, The Journal of hand surgery.
[28] Y. Aizawa. On the organization of the Plexus lumbalis. I. On the recognition of the three-layered divisions and the systematic description of the branches of the human femoral nerve. , 1992, Okajimas folia anatomica Japonica.
[29] K. Kilgore,et al. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. , 2001, Archives of physical medicine and rehabilitation.
[30] R Kobetic,et al. Augmentation of transfers for a quadriplegic patient using an implanted FNS system. Case report , 1994, Paraplegia.
[31] Daniel K. Leventhal,et al. Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.