Assessing Distortion Within the IEC Framework in the Presence of High Frequency Components: Some Considerations on Signal Processing

Assessing distortion within the lEC framework in the presence of high frequency (HF) components is considered in this paper from the perspective of signal processing. To reduce uncertainty when assessing HF distortion, the lEC suggests the use of a high-pass filter, which can be analogue (with a dedicated channel for HF assessment) or integrated in its digital form into the signal processing stage. This paper extends the proven desynchronized processing technique (DPT), previously introduced for harmonic and interharmonic analysis, as an alternative filtering technique and compares its performance against three digital filtering techniques presented in literature. Particular attention is paid to the error introduced by the desynchronization of the fundamental frequency, which naturally deviates from its rated value, with the fixed 200ms window recommended by the lEC for HF distortion assessment. Two case studies highlight the strengths and weaknesses of the techniques and demonstrate the potential of the DPT to analyse HF distortion.

[1]  Paulo F. Ribeiro Time-Varying Waveform Distortions in Power Systems , 2009 .

[2]  Jiri Drapela,et al.  Frequency response of revenue meters in measured active energy , 2016, 2016 17th International Conference on Harmonics and Quality of Power (ICHQP).

[3]  A. Testa,et al.  Desynchronized Processing technique for Harmonic and interharmonic analysis , 2004, IEEE Transactions on Power Delivery.

[4]  Matthias Klatt,et al.  Filter for the measurement of supraharmonics in public low voltage networks , 2015, 2015 IEEE International Symposium on Electromagnetic Compatibility (EMC).

[5]  Guido Carpinelli,et al.  New ESPRIT-based method for an efficient assessment of waveform distortions in power systems , 2015 .

[6]  Maria Emília de Lima Tostes,et al.  Characterization of supraharmonics using the wavelet packet transform , 2018, 2018 18th International Conference on Harmonics and Quality of Power (ICHQP).

[7]  P. Schegner,et al.  Topology identification of electronic mass-market equipment for estimation of lifetime reduction by HF disturbances above 2 kHz , 2017, 2017 IEEE Manchester PowerTech.

[8]  Cheng-I Chen,et al.  Measurement techniques for stationary and time-varying harmonics , 2010, IEEE PES General Meeting.

[9]  Paulo F. Ribeiro,et al.  On waveform distortion in the frequency range of 2 kHz–150 kHz—Review and research challenges , 2017 .

[10]  Julio Barros,et al.  Analysis of Harmonics in Power Systems Using the Wavelet-Packet Transform , 2005, IEEE Transactions on Instrumentation and Measurement.

[11]  E O Anders Larsson,et al.  Measurements of High-Frequency (2–150 kHz) Distortion in Low-Voltage Networks , 2010, IEEE Transactions on Power Delivery.

[12]  W. R. Bennett,et al.  Spectra of quantized signals , 1948, Bell Syst. Tech. J..

[13]  Matthias Klatt,et al.  Comparison of measurement methods for the frequency range of 2 kHz to 150 kHz , 2014, 2014 16th International Conference on Harmonics and Quality of Power (ICHQP).

[14]  Anders Larsson,et al.  A Wavelet-Modified ESPRIT Hybrid Method for Assessment of Spectral Components from 0 to 150 kHz , 2017 .