Dielectric spectroscopy in time and frequency domain on insulation system of high voltage rotating machines

In this work the relations between the time and frequency domain parameters of the dielectric spectroscopy will be discussed. Then the results of dielectric response measurements in time and frequency domain on the insulation systems which are used for high voltage rotating machines will be reported. As test object, actual stator bars were used based on the epoxy VPI technology. The linearity of the insulation system will be checked and the possibility to transfer the measuring data from one domain to another investigated. The paper compares the calculated and measured data and shows the influence of difference parameter.

[1]  B. V. Hamon,et al.  An approximate method for deducing dielectric loss factor from direct-current measurements , 1952 .

[2]  A. Jonscher Dielectric relaxation in solids , 1983 .

[3]  Vahe Der Houhanessian,et al.  Measurement and analysis of dielectric response in oil-paper insulation systems , 1998 .

[4]  U. Gafvert,et al.  Dielectric response measurements in time and frequency domain on high voltage insulation with different response , 1998, Proceedings of 1998 International Symposium on Electrical Insulating Materials. 1998 Asian International Conference on Dielectrics and Electrical Insulation. 30th Symposium on Electrical Insulating Ma.

[5]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .