A Software Tool for Analyzing Multichannel Cochlear Implant Signals

A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

[1]  G F Smoorenburg,et al.  Recognition of Dutch phonemes by cochlear implant users with the Multipeak strategy. , 1995, The Annals of otology, rhinology & laryngology. Supplement.

[2]  J K Shallop,et al.  Evaluation of a new spectral peak coding strategy for the Nucleus 22 Channel Cochlear Implant System. , 1994, The American journal of otology.

[3]  Dennis G. Pappas Book Review: The Child and the Environment — Present and Future Trends , 1995 .

[4]  P Seligman,et al.  Architecture of the Spectra 22 speech processor. , 1995, The Annals of otology, rhinology & laryngology. Supplement.

[5]  W K Lai,et al.  A hybrid coding strategy for a multichannel cochlear implant. , 1993, Advances in oto-rhino-laryngology.

[6]  D. D. Greenwood A cochlear frequency-position function for several species--29 years later. , 1990, The Journal of the Acoustical Society of America.

[7]  N. Dillier,et al.  Electrodographic analysis and field evaluation of the Speak coding strategy. , 1995, The Annals of otology, rhinology & laryngology. Supplement.

[8]  R V Shannon,et al.  Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor. , 1997, Journal of speech, language, and hearing research : JSLHR.

[9]  Colleen Psarros,et al.  Speech Recognition with the Nucleus 24 SPEAK, ACE, and CIS Speech Coding Strategies in Newly Implanted Adults , 2002, Ear and hearing.

[10]  M. Demorest,et al.  Speech recognition at simulated soft, conversational, and raised-to-loud vocal efforts by adults with cochlear implants. , 1997, The Journal of the Acoustical Society of America.

[11]  F G Zeng,et al.  Amplitude mapping and phoneme recognition in cochlear implant listeners. , 1999, Ear and hearing.

[12]  N Dillier,et al.  Wearable digital speech processor for cochlear implants using a TMS320C25. , 1990, Acta oto-laryngologica. Supplementum.

[13]  T Spillmann,et al.  Speech encoding strategies for multielectrode cochlear implants: a digital signal processor approach. , 1993, Progress in brain research.