Robustness of the extraction step when parallel factor analysis (PARAFAC) is used to quantify sulfonamides in kidney by high performance liquid chromatography-diode array detection (HPLC-DAD).

The robustness of a multiresidue method has been analysed for the extraction and quantification of sulfamethoxypyridazine, sulfamethoxazole and sulfadimethoxine in porcine kidney by HPLC-DAD through a Plackett-Burman design. Two experimental responses were examined, the mean recovery from three replicates (accuracy) and their standard deviation (precision). Three factors were tested: the volume of phosphoric acid (pH) added in the extraction step, the time used for passing the sample through the solid-phase extraction cartridge (flow rate) and methanol volume to elute the analytes from the cartridge. Due to the non-specificity of the chromatograms (unknown matrix interferences coelute with each sulfonamide) the PARAFAC model was employed to evaluate the concentration recovered in the experiments of the Plackett-Burman design as well as to identify the spectra of the substances according to the criteria set in the European Decision 2002/657/EC for the analysis of residues. The extraction step was concluded to be robust to the recovery and the standard deviation of all three analytes.

[1]  R. Plackett,et al.  THE DESIGN OF OPTIMUM MULTIFACTORIAL EXPERIMENTS , 1946 .

[2]  R. Lenth Quick and easy analysis of unreplicated factorials , 1989 .

[3]  M. Quilliam,et al.  Determination of sulfonamides by liquid chromatography, ultraviolet diode array detection and ion-spray tandem mass spectrometry with application to cultured salmon flesh. , 1991, Journal of chromatography.

[4]  Bruce R. Kowalski,et al.  A second‐order standard addition method with application to calibration of a kinetics–spectroscopic sensor for quantitation of trichloroethylene , 1995 .

[5]  Helmut Günzler,et al.  Accreditation and quality assurance in analytical chemistry , 1996 .

[6]  S. Crooks,et al.  Immunobiosensor--an alternative to enzyme immunoassay screening for residues of two sulfonamides in pigs. , 1998, The Analyst.

[7]  E. Wang,et al.  Determination of sulfadiazine and sulfamethoxazole by capillary electrophoresis with end-column electrochemical detection. , 1998, The Analyst.

[8]  R. Bro Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis , 1999 .

[9]  Rasmus Bro,et al.  The N-way Toolbox for MATLAB , 2000 .

[10]  N. Furusawa,et al.  Simplified determining procedure for routine residue monitoring of sulphamethazine and sulphadimethoxine in milk. , 2000, Journal of chromatography. A.

[11]  H. Nagase,et al.  Application of ion-exchange cartridge clean-up in food analysis. V. Simultaneous determination of sulphonamide antibacterials in animal liver and kidney using high-performance liquid chromatography with ultraviolet and mass spectrometric detection. , 2000, Journal of chromatography. A.

[12]  C. V. Van Peteghem,et al.  Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up. , 2000, Rapid communications in mass spectrometry : RCM.

[13]  Akira Fujishima,et al.  Electroanalytical study of sulfa drugs at diamond electrodes and their determination by HPLC with amperometric detection , 2000 .

[14]  C. Poole,et al.  Contributions of theory to method development in solid-phase extraction. , 2000, Journal of chromatography. A.

[15]  N. Furusawa,et al.  Matrix solid-phase dispersion extraction and high-performance liquid chromatographic determination of residual sulfonamides in chicken. , 2001, Journal of chromatography. A.

[16]  R. Stadler,et al.  Application of liquid chromatography-electrospray ionization tandem mass spectrometry to the detection of 10 sulfonamides in honey. , 2002, Journal of chromatography. A.

[17]  M. C. Ortiz,et al.  A study of robustness with multivariate calibration. Application to the polarographic determination of benzaldehyde. , 2002, Talanta.

[18]  T. Msagati,et al.  Voltammetric detection of sulfonamides at a poly(3-methylthiophene) electrode. , 2002, Talanta.

[19]  G. Pang,et al.  Liquid chromatography–fluorescence detection for simultaneous analysis of sulfonamide residues in honey , 2003, Analytical and bioanalytical chemistry.

[20]  M. C. Ortiz,et al.  Advances in methodology for the validation of methods according to the International Organization for Standardization. Application to the determination of benzoic and sorbic acids in soft drinks by high-performance liquid chromatography. , 2003, Journal of chromatography. A.

[21]  Rasmus Bro,et al.  Recent developments in CANDECOMP/PARAFAC algorithms: a critical review , 2003 .