A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.

PURPOSE To compare the biomechanic stability of distal radius fracture fixation with a new internal radiocarpal-spanning 2.4-mm locking plate, which acts as an internal distal radius fixator, versus a standard distal radius external fixator. The number of locking screws necessary for adequate fracture fixation was also assessed. METHODS Ten cadaveric specimens were mounted in a loading fixture with cables attached to the 2 flexor and 3 extensor wrist tendons. A 1-cm osteotomy was created to simulate an unstable distal radius fracture. The radiocarpal-spanning locking plate was fixed to the radius and index metacarpal with 4 screws proximally and 4 distally. The specimen was incrementally loaded through the tendons. Motion at the fracture site was determined. Screws were sequentially removed from the construct, the specimen was again incrementally loaded, and fracture motion was measured. The fixation was then changed to an external fixator, and the loading tests were repeated. RESULTS Fracture fixation with the radiocarpal-spanning 2.4-mm locking plate was significantly more stable with 4 screws proximally and 4 screws distally (4 x 4) and with the 3 x 3 configuration than with the external fixator in both flexion and extension. The 4 x 4 screw configuration was not significantly different from the 3 x 3 screw configuration. The 4 x 4 screw configuration was significantly more stable than the 2 x 2 and 1 x 1 screw configurations in both flexion and extension. All internal fixator configurations and the external fixator showed more fracture displacement at increasingly higher loads. CONCLUSIONS Fracture fixation with the new internal radiocarpal-spanning 2.4-mm locking plate is more stable than with a standard distal radius external fixator. Only three 2.4-mm locking screws proximally and three 2.4-mm locking screws distally are required for adequate fixation of the locking spanning plate.

[1]  G. Volpin,et al.  The surgical treatment of severe comminuted intraarticular fractures of the distal radius with the small AO external fixation device. A prospective three-and-one-half-year follow-up study. , 1991, Clinical orthopaedics and related research.

[2]  S. D. Dodds,et al.  A biomechanical comparison of fragment-specific fixation and augmented external fixation for intra-articular distal radius fractures. , 2002, The Journal of hand surgery.

[3]  U. Joosten,et al.  Results of transarticular fixator application in distal radius fractures. , 2000, Injury.

[4]  R. Singer,et al.  Treatment of comminuted distal radius with the use of an internal distraction plate. , 1998, Techniques in hand & upper extremity surgery.

[5]  D. Fernández,et al.  History, evolution and biomechanics of external fixation of the wrist joint. , 1994, Injury.

[6]  C. Court-Brown,et al.  Hand and wrist function after external fixation of unstable distal radial fractures. , 1992, Clinical orthopaedics and related research.

[7]  I. Jakim,et al.  External fixation for intra-articular fractures of the distal radius. , 1991, The Journal of bone and joint surgery. British volume.

[8]  F. Behrens,et al.  Unilateral external fixation. Methods to increase and reduce frame stiffness. , 1989, Clinical orthopaedics and related research.

[9]  J. E. Hale,et al.  Biomechanical Efficacy of an Internal Fixator for Treatment of Distal Radius Fractures , 2001, Clinical orthopaedics and related research.

[10]  F. Kaempffe,et al.  External Fixation for Distal Radius Fractures: Effect of Distraction on Outcome , 2000, Clinical Orthopaedics and Related Research.

[11]  S. Wolfe,et al.  Load-displacement behavior in a distal radial fracture model. The effect of simulated healing on motion. , 1999, The Journal of bone and joint surgery. American volume.

[12]  J. Jupiter,et al.  Fracture of the distal radius: classification of treatment and indications for external fixation. , 1994, Injury.

[13]  G. Edwards Intra-articular fractures of the distal part of the radius treated with the small AO external fixator. , 1991, The Journal of bone and joint surgery. American volume.

[14]  R. Sanders,et al.  External fixation of distal radial fractures: results and complications. , 1991, The Journal of hand surgery.

[15]  H. M. Dick,et al.  Limited open surgical approach for external fixation of distal radius fractures. , 1990, The Journal of hand surgery.

[16]  M. Bishay,et al.  The Results of External Fixation of the Radius in the Treatment of Comminuted Intraarticular Fractures of the Distal End , 1994, Journal of hand surgery.

[17]  K. Koval,et al.  A Biomechanical Comparison of a Dorsal 3.5-mm T-Plate and a Volar Fixed-Angle Plate in a Model of Dorsally Unstable Distal Radius Fractures , 2005, Journal of orthopaedic trauma.

[18]  S. Suso,et al.  Comminuted intra-articular fractures of the distal end of the radius treated with the Hoffmann external fixator. , 1993, The Journal of trauma.

[19]  C. Court-Brown,et al.  Use of the Hoffman 2 compact external fixator in the treatment of redisplaced unstable distal radial fractures. , 1999, Journal of orthopaedic trauma.

[20]  G. Colborn,et al.  Use of an internal fixator device to treat comminuted fractures of the distal radius: report of a technique. , 1998, American journal of orthopedics.

[21]  J. Lunn,et al.  External fixation of distal radial fractures. , 2000, Injury.

[22]  Melone Cp,et al.  Unstable articular fractures of the distal radius. Comparative techniques of ligamentotaxis. , 1993 .

[23]  S. Wolfe,et al.  A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. , 1999, The Journal of hand surgery.

[24]  Cooney Wp,et al.  External fixation of distal radial fractures. , 1983 .

[25]  D. Ruch,et al.  Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution. , 2005, The Journal of bone and joint surgery. American volume.

[26]  J. Bennett,et al.  Complications of distal radial fractures: pins and plaster treatment. , 1982, The Journal of hand surgery.

[27]  M M Panjabi,et al.  Augmented external fixation of distal radius fractures: a biomechanical analysis. , 1998, The Journal of hand surgery.

[28]  J. Slavotinek,et al.  Intra-Articular Fractures of the Distal Radius: A Prospective Randomised Controlled Trial Comparing Static Bridging and Dynamic Non-Bridging External Fixation , 2003, Journal of hand surgery.

[29]  W P Cooney,et al.  Complications of Colles' fractures. , 1980, The Journal of bone and joint surgery. American volume.

[30]  E. Chao,et al.  Comparison of osteotomy healing under external fixation devices with different stiffness characteristics. , 1984, The Journal of bone and joint surgery. American volume.

[31]  H. Kapoor,et al.  Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. , 2000, Injury.

[32]  J. Ellis Smith's and Barton's fractures. A method of treatment. , 1965, The Journal of bone and joint surgery. British volume.

[33]  Z. Horesh The surgical treatment of severe comminuted intraarticular fractures of the distal radius with the small A0 external fixation device. , 1991 .