Competitive capacitive biosensing technique (CCBT): A novel technique for monitoring low molecular mass analytes using glucose assay as a model study

A novel technique for monitoring of low molecular mass analytes using a flow-injection capacitive biosensor is presented. The method is based on the ability of a small molecular mass analyte to displace a large analyte–carrier conjugate from the binding sites of an immobilized biorecognition element with weak affinity to both compounds. A model study was performed on glucose as the small molecular mass analyte. In the absence of glucose, binding of a glucose polymer or a glycoconjugate to concanavalin A results in a capacitance decrease. Upon introduction of glucose, it displaces a part of the bound glucose polymer or glycoconjugate leading to a partial restoration of capacitance. Experimental results show that the change in capacitance depends linearly on glucose concentration within the range from 1.0 × 10−5 to 1.0 × 10−1 M, corresponding to 1.8 µg ml−1 to 18 mg ml−1 in a logarithmic plot, with a detection limit of 1.0 × 10−6 (0.18 µg ml−1) under optimized conditions. In addition, by modifying the molecular mass of the glucose polymer, amount of biorecognition element, and buffer composition, we were able to tune the analyte-sensing range. The developed technique has the benefits of expanded dynamic range, high sensitivity, and excellent reusability.

[1]  O. Khalil,et al.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. , 2004, Diabetes technology & therapeutics.

[2]  Baohong Liu,et al.  Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement. , 2003, Biosensors & bioelectronics.

[3]  M. Bergström,et al.  Evaluation of a glucose sensing antibody using weak affinity chromatography. , 2008, Biomedical chromatography : BMC.

[4]  Sergey A. Piletsky,et al.  Rational design of a polymer specific for microcystin-LR using a computational approach. , 2002, Analytical chemistry.

[5]  Blood glucose monitor: an alternative off-line method to measure glucose concentration during fermentations with Trichoderma reesei , 2007, Biotechnology Letters.

[6]  G. Johansson,et al.  Capacitance measurements of antibody-antigen interactions in a flow system. , 1997, Analytical chemistry.

[7]  Wang,et al.  On-line monitoring and controlling system for fermentation processes. , 2001, Biochemical engineering journal.

[8]  O. Rolinski,et al.  Near-infrared fluorescence lifetime assay for serum glucose based on allophycocyanin-labeled concanavalin A. , 2001, Analytical biochemistry.

[9]  J. Schultz,et al.  Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites , 1982, Diabetes Care.

[10]  M. Mcshane,et al.  Resonance energy transfer nanobiosensors based on affinity binding between apo-enzyme and its substrate. , 2004, Biomacromolecules.

[11]  Johannis P Kamerling,et al.  Identification of carbohydrates binding to lectins by using surface plasmon resonance in combination with HPLC profiling. , 2004, Glycobiology.

[12]  G. Johansson,et al.  An immunological interleukine-6 capacitive biosensor using perturbation with a potentiostatic step. , 1998, Biosensors & bioelectronics.

[13]  A. Ramanavičius,et al.  Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode , 2004, Analytical and bioanalytical chemistry.

[14]  C. Malitesta,et al.  Molecularly imprinted electrosynthesized polymers:  new materials for biomimetic sensors. , 1999, Analytical chemistry.

[15]  U. Haueter,et al.  Clinical performance of a continuous viscometric affinity sensor for glucose. , 2004, Diabetes technology & therapeutics.

[16]  Dieter Trau,et al.  Reusable optical bioassay platform with permeability-controlled hydrogel pads for selective saccharide detection. , 2008, Analytica chimica acta.

[17]  Bo Mattiasson,et al.  A capacitive biosensor for detection of staphylococcal enterotoxin B , 2009, Analytical and bioanalytical chemistry.

[18]  Jian Zhang,et al.  Saccharide Sensing Using Gold and Silver Nanoparticles-A Review , 2004, Journal of Fluorescence.

[19]  Kadir Aslan,et al.  Nanogold-plasmon-resonance-based glucose sensing. , 2004, Analytical biochemistry.

[20]  A. Turner,et al.  The synthesis and screening of a combinatorial peptide library for affinity ligands for glycosylated haemoglobin. , 1998, Biosensors & bioelectronics.

[21]  Hope T. Beier,et al.  Microporated PEG Spheres for Fluorescent Analyte Detection , 2006, Journal of Fluorescence.

[22]  M Rossi,et al.  A thermophilic apoglucose dehydrogenase as nonconsuming glucose sensor. , 2000, Biochemical and biophysical research communications.

[23]  Kaiming Ye,et al.  Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer. , 2003, Analytical chemistry.

[24]  V. Nesatyy,et al.  On the conformation-dependent neutralization theory and charging of individual proteins and their non-covalent complexes in the gas phase. , 2004, Journal of mass spectrometry : JMS.

[25]  G. Johansson,et al.  Instrumentation for Direct Capacitive Biosensors , 1999 .

[26]  Boris Kovatchev,et al.  A Critical Appraisal of the Continuous Glucose–Error Grid Analysis , 2007, Diabetes Care.

[27]  N. Evans,et al.  Fluorescence-based glucose sensors. , 2005, Biosensors & bioelectronics.

[28]  Zygmunt Gryczynski,et al.  A novel fluorescence competitive assay for glucose determinations by using a thermostable glucokinase from the thermophilic microorganism Bacillus stearothermophilus. , 2002, Analytical biochemistry.

[29]  U. Haueter,et al.  Calibration of the viscometric glucose sensor before its use in physiological liquids--compensation for the colloid-osmotic effect. , 2003, Biosensors & bioelectronics.

[30]  I. Goldstein,et al.  Protein-carbohydrate interaction. XX. On the number of combining sites on concanavalin A, the phytohemagglutinin of the jack bean. , 1968, Biochimica et biophysica acta.

[31]  Bo Mattiasson,et al.  A multipurpose capacitive biosensor for assay and quality control of human immunoglobulin G , 2009, Biotechnology and bioengineering.

[32]  Bo Mattiasson,et al.  A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode. , 2010, Analytica chimica acta.

[33]  M. Motamedi,et al.  Affinity-based turbidity sensor for glucose monitoring by optical coherence tomography: toward the development of an implantable sensor. , 2007, Analytical chemistry.

[34]  Bo Mattiasson,et al.  A capacitive immunosensor for detection of cholera toxin. , 2009, Analytica chimica acta.

[35]  Booncharoen Wongkittisuksa,et al.  Capacitive biosensor for quantification of trace amounts of DNA. , 2009, Biosensors & bioelectronics.

[36]  Arunas Ramanavicius,et al.  Molecularly imprinted polypyrrole-based synthetic receptor for direct detection of bovine leukemia virus glycoproteins. , 2004, Biosensors & bioelectronics.

[37]  B. Mattiasson,et al.  Thin semitransparent gels containing phenylboronic acid: porosity, optical response and permeability for sugars , 2008, Journal of molecular recognition : JMR.

[38]  Jason E Gestwicki,et al.  Influencing receptor-ligand binding mechanisms with multivalent ligand architecture. , 2002, Journal of the American Chemical Society.

[39]  Laura Marcu,et al.  Design and fabrication of disposable percutaneous chemical sensors , 2005, SPIE BiOS.

[40]  A. Turner,et al.  "Bite-and-Switch" approach using computationally designed molecularly imprinted polymers for sensing of creatinine. , 2001, Biosensors & bioelectronics.

[41]  E. Sevick-Muraca,et al.  Measurements of FRET in a Glucose-sensitive Affinity System with Frequency-domain Lifetime Spectroscopy , 2005, Photochemistry and photobiology.

[42]  E. Csöregi,et al.  Highly Sensitive Novel Biosensor Based on an Immobilized lac Repressor. , 2001, Angewandte Chemie.

[43]  D. Mandal,et al.  Thermodynamics of lectin-carbohydrate interactions. Titration microcalorimetry measurements of the binding of N-linked carbohydrates and ovalbumin to concanavalin A. , 1994, Biochemistry.

[44]  J. Anzai,et al.  Fluorometric determination of sugars using fluorescein-labeled concanavalin A–glycogen conjugates , 2006, Analytical and bioanalytical chemistry.

[45]  A. Turner,et al.  Application of molecularly imprinted polymers in sensors for the environment and biotechnology , 2001 .

[46]  V. Pérez-Luna,et al.  Dextran-gold nanoparticle hybrid material for biomolecule immobilization and detection. , 2005, Analytical chemistry.