An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging

Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, temporal resolution of TR-CBCT imaging can be improved. One such an example is the use of Simultaneous Multiple Artifacts Reduction in Tomographic RECONstruction (SMART-RECON) [1] technique. However, with SMART-RECON, one can only improve temporal resolution up to 1 frame per second (fps) which is an improvement of 4.5 times over that of the conventional FBP reconstruction. In this paper, a new technique referred to as enhanced SMART-RECON (eSMART-RECON) was introduced to enhance the temporal performance of SMART-RECON in a multi-sweep CBCT data acquisition protocol. Both numerical simulation studies with ground truth and in vivo human subject studies using C-arm CBCT acquisition systems were conducted to demonstrate the following key results: for a multi-sweep CBCT acquisition protocol, eSMART-RECON enables 4–7.5 fps temporal resolution for TR-CBCT which is 4–7.5 times better than that offered by the original SMART-RECON, and 18–34 times better than that offered by the conventional FBP reconstruction.

[1]  Emmanuel J. Candès,et al.  A Singular Value Thresholding Algorithm for Matrix Completion , 2008, SIAM J. Optim..

[2]  Kai Niu,et al.  Statistical image reconstruction via denoised ordered-subset statistically penalized algebraic reconstruction technique (DOS-SPART) , 2014, Medical Imaging.

[3]  Guang-Hong Chen,et al.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT. , 2015, Medical physics.

[4]  Christoph Neukirchen,et al.  An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach. , 2010, Medical physics.

[5]  C Picard,et al.  In vivo evaluation of a new system for 3D computerized angiography. , 1994, Physics in medicine and biology.

[6]  T Struffert,et al.  Dynamic Angiography and Perfusion Imaging Using Flat Detector CT in the Angiography Suite: A Pilot Study in Patients with Acute Middle Cerebral Artery Occlusions , 2015, American Journal of Neuroradiology.

[7]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[8]  O. Gurvit,et al.  A Jacobi-like solution to the model based tomographic X-ray perfusion imaging , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[9]  Jan Sijbers,et al.  Local attenuation curve optimization framework for high quality perfusion maps in low-dose cerebral perfusion CT. , 2016, Medical physics.

[10]  R A Kruger,et al.  Image intensifier-based computed tomography volume scanner for angiography. , 1996, Academic radiology.

[11]  R A Kruger,et al.  Computerized fluoroscopy: digital subtraction for intravenous angiocardiography and arteriography. , 1980, AJR. American journal of roentgenology.

[12]  Kevin Royalty,et al.  Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology , 2014, European Radiology.

[13]  Guang-Hong Chen,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009, Medical physics.

[14]  G. Cornelis,et al.  Rotational Multiple Sequence Roentgenography of Intracranial Aneurysms , 1972, Acta radiologica: diagnosis.

[15]  Andreas Maier,et al.  Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction , 2012, Medical Imaging.

[16]  Patrick L. Combettes,et al.  Signal Recovery by Proximal Forward-Backward Splitting , 2005, Multiscale Model. Simul..

[17]  Charles Mistretta Digital subtraction arteriography : an application of computerized fluoroscopy , 1982 .

[18]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[19]  Jie Tang,et al.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies. , 2010, Medical physics.

[20]  Guang-Hong Chen,et al.  Quantification of temporal resolution improvement factor in SMART-RECON based time-resolved C-arm Cone beam computed tomography angiography (TR-CBCTA). , 2018, Physics in medicine and biology.

[21]  Ke Li,et al.  Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction. , 2018, Medical physics.

[22]  D. Holdsworth,et al.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. , 1997, AJNR. American journal of neuroradiology.

[23]  Andreas K. Maier,et al.  Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging , 2013, IEEE Transactions on Medical Imaging.

[24]  R A Kruger,et al.  Clinical applications of computerized fluoroscopy: the extracranial carotid arteries. , 1980, Radiology.

[25]  Rebecca Fahrig,et al.  Interventional 4-D C-Arm CT Perfusion Imaging Using Interleaved Scanning and Partial Reconstruction Interpolation , 2012, IEEE Transactions on Medical Imaging.

[26]  Ke Li,et al.  Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection , 2018, Physics in medicine and biology.

[27]  L. Landweber An iteration formula for Fredholm integral equations of the first kind , 1951 .

[28]  T Togawa,et al.  Optimal branching structure of the vascular tree. , 1972, The Bulletin of mathematical biophysics.

[29]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[30]  Y Wu,et al.  C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging , 2016, American Journal of Neuroradiology.

[31]  Guang-Hong Chen,et al.  Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite , 2015, Stroke.

[32]  Kai Niu,et al.  A novel temporal recovery technique to enable cone beam CT perfusion imaging using an interventional C-arm system , 2013, Medical Imaging.

[33]  D. Petersen,et al.  Rotational cerebral roentgenography , 1975, Neuroradiology.

[34]  Martin Wagner,et al.  A model based algorithm for perfusion estimation in interventional C-arm CT systems. , 2013, Medical physics.