X-ray imaging spectrometers for Astro-E: ground calibration in the soft x-ray range

Soft X-ray response of X-ray Imaging Spectrometers (XIS) for the Astro-E satellite is measured with a grating spectrometer system at Osaka. First, relation between incident X-ray energy and output pulse height peak (E-PH relation) is examined with an SX grating. It is found that jump in the E-PH relation around Si-K edge is at most 2.7 eV. Second, quantum efficiency (QE) of the XIS in 0.4 - 2.2 keV range is measured relatively to the reference CCD of which absolute QE was calibrated with a gas proportional counter. The QE is fitted with a model in which CCD gate structures are considered. Systematic error on the QE results is estimated by referring an independent measurement. Third, tuning and improvement of the response function is performed. We employ six components to reproduce the response profile of the XIS. In this paper, improvement of one component which is originated in the events absorbed in the channel-stop is presented. Nevertheless, Astro-E was lost due to the launch failure. We overview the XIS project in its flight model phase, modified points of the design, problems and solutions etc., in order to be utilized in a possible recovery of the satellite.

[1]  Emi Miyata,et al.  Quantum efficiency of the CCD camera (XIS) for the ASTRO-E mission , 1999 .

[2]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[3]  Emi Miyata,et al.  Some characteristics of a solid state detector in the soft X-ray region , 1995 .

[4]  Emi Miyata,et al.  Calibration of the X-ray CCD camera (XIS) for the ASTRO-E in the soft-x-ray band , 1999, Optics & Photonics.

[5]  H. Murakami,et al.  The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector , 1999 .

[6]  G. Ricker,et al.  Reports of soft X-ray response of the engineering model of the CCD camera (XIS) for the ASTRO-E mission , 2000 .

[7]  Gregory Y. Prigozhin,et al.  Model of the x-ray response of the ACIS CCD , 1998, Optics & Photonics.

[8]  Emi Miyata,et al.  Quantum efficiency measurement of the x-ray CCD camera (XIS) for the ASTRO-E mission in the soft-x-ray band , 1999, Optics & Photonics.

[9]  K. Koyama,et al.  Continuum x-ray source as a calibration system for charge coupled devices , 1998 .

[10]  Hiroshi Murakami,et al.  High-energy performance of x-ray imaging spectrometers on board Astro-E , 2000, Astronomical Telescopes and Instrumentation.

[11]  G. Ricker,et al.  Soft X-ray response of a CCD with a grating spectrometer , 1999 .

[12]  Hiroshi Tsunemi,et al.  Response function of an x-ray CCD camera on board the Astro-E satellite , 1998, Optics & Photonics.

[13]  Emi Miyata,et al.  Characteristics around oxygen and silicon K absorption edges of a charge-coupled device , 2000, Astronomical Telescopes and Instrumentation.

[14]  Beverly LaMarr,et al.  Radiation damage in the Chandra x-ray CCDs , 2000, Astronomical Telescopes and Instrumentation.

[15]  Alan A. Wells,et al.  The X-ray energy response of silicon Part A. Theory , 1994 .

[16]  Michael J. Pivovaroff,et al.  X-ray CCD calibration for the AXAF CCD Imaging Spectrometer , 1996, Optics & Photonics.

[17]  Emi Miyata,et al.  Soft x-ray response of the prototype CCD camera (XIS) for Astro-E , 1998, Optics & Photonics.

[18]  Hiroshi Murakami,et al.  New event analysis method with the x-ray CCD camera XIS for ASTRO-E , 1999, Optics & Photonics.

[19]  Emi Miyata,et al.  Properties of the optical blocking filter of the XIS for the ASTRO-E mission , 2000 .

[20]  Michael J. Pivovaroff,et al.  Measurement of the subpixel structure of AXAF CCD's , 1998 .