A reliable and rapid method for molecular detection of malarial parasites using microwave irradiation and loop mediated isothermal amplification

BackgroundImproved living conditions together with appropriate diagnosis can reduce avoidable malarial deaths substantially. Microscopy remains the gold standard in the diagnosis of malaria. However, rapid molecular diagnostic tests (RmDT) are becoming increasingly important and will, most likely, be the diagnostic techniques of choice in the next years.MethodsIn this study, a rapid and reliable nucleic acid extraction procedure from human blood and malarial parasites using microwave irradiation as a promising platform is described. In addition, a tailored loop mediated isothermal amplification (LAMP) methodology that utilizes hydroxynaphthol blue (HNB) and Bst 2.0 DNA polymerases in molecular detection of malarial parasites is described.ResultsFollowing microwave irradiation for DNA isolation, conventional PCR assays were able to detect up to five malaria parasites/μl. The LAMP methodology described here was capable to detect as low as one Plasmodium falciparum parasite/μl after DNA extraction by microwave irradiation. A turnover time of 45 minutes from nucleic acid extraction to final visual read-out was achieved.ConclusionsThe described procedure offers a cheap, simple and fast method of molecular detection of malaria parasites. This test can easily be performed in basic laboratories. The methodology has been validated as a proof of concept and has specifically be developed for use at low-resource settings. Such RmDTs may aid health providers to make timely therapeutic interventions in malaria endemic regions.

[1]  A. Aseffa,et al.  Re-evaluation of microscopy confirmed Plasmodium falciparum and Plasmodium vivax malaria by nested PCR detection in southern Ethiopia , 2014, Malaria Journal.

[2]  Solomon Ali,et al.  Evaluation of the performance of CareStart Malaria Pf/Pv Combo rapid diagnostic test for the diagnosis of malaria in Jimma, southwestern Ethiopia. , 2010, Acta tropica.

[3]  Eun-Taek Han,et al.  Detection of Four Plasmodium Species by Genus- and Species-Specific Loop-Mediated Isothermal Amplification for Clinical Diagnosis , 2007, Journal of Clinical Microbiology.

[4]  T. Notomi,et al.  Loop-mediated isothermal amplification of DNA. , 2000, Nucleic acids research.

[5]  Yi Guan,et al.  Sensitive and inexpensive molecular test for falciparum malaria: detecting Plasmodium falciparum DNA directly from heat-treated blood by loop-mediated isothermal amplification. , 2006, Clinical chemistry.

[6]  M. Gatton,et al.  Malaria rapid diagnostic test performance : results of WHO product testing of malaria RDTs : round 5 (2013) , 2018 .

[7]  敦子 伊藤,et al.  ヒドロキシナフトールブルー(HNB)指示薬を用いるカルシウム,マグネシウムの連続キレート滴定 , 1970 .

[8]  Teun Bousema,et al.  Targeting Asymptomatic Malaria Infections: Active Surveillance in Control and Elimination , 2013, PLoS medicine.

[9]  J. Sattabongkot,et al.  Evaluation of loop-mediated isothermal amplification (LAMP) for malaria diagnosis in a field setting. , 2011, The American journal of tropical medicine and hygiene.

[10]  A. Aseffa,et al.  Return of chloroquine-sensitive Plasmodium falciparum parasites and emergence of chloroquine-resistant Plasmodium vivax in Ethiopia , 2014, Malaria Journal.

[11]  Mehul Dhorda,et al.  Performance of a histidine-rich protein 2 rapid diagnostic test, Paracheck Pf®, for detection of malaria infections in Ugandan pregnant women. , 2012, The American journal of tropical medicine and hygiene.

[12]  T. Gebre,et al.  Performance of Local Light Microscopy and the ParaScreen Pan/Pf Rapid Diagnostic Test to Detect Malaria in Health Centers in Northwest Ethiopia , 2012, PloS one.

[13]  Saorin Kim,et al.  Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections , 2012, Malaria Journal.

[14]  T. C. Evans,et al.  Loop‐Mediated Isothermal Amplification for Detection of Nucleic Acids , 2014, Current protocols in molecular biology.

[15]  I. González,et al.  Loop Mediated Isothermal Amplification (LAMP) Accurately Detects Malaria DNA from Filter Paper Blood Samples of Low Density Parasitaemias , 2014, PloS one.

[16]  V. do Rosário,et al.  Application of loop-mediated isothermal amplification for malaria diagnosis during a follow-up study in São Tomé , 2012, Malaria Journal.

[17]  J. Skarbinski,et al.  Comparative field performance and adherence to test results of four malaria rapid diagnostic tests among febrile patients more than five years of age in Blantyre, Malawi , 2010, Malaria Journal.

[18]  Colin J. Sutherland,et al.  Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification , 2010, Journal of Clinical Microbiology.

[19]  J. Sánchez-Tapias,et al.  Microwave treatment of serum facilitates detection of hepatitis B virus DNA by the polymerase chain reaction. Results of a study in anti-HBe positive chronic hepatitis B. , 1995, Journal of hepatology.

[20]  Rashidul Haque,et al.  A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria , 2014, Acta Tropica.

[21]  P. Blouin,et al.  Improved detection of HBV DNA by PCR after microwave treatment of serum. , 1991, Nucleic acids research.

[22]  P. Kremsner,et al.  Combined promoter haplotypes of the IL10R genes are associated with protection against severe malaria in Gabonese children , 2011, Immunogenetics.

[23]  Eiichi Honda,et al.  Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. , 2009, BioTechniques.

[24]  V. Nissapatorn,et al.  Detection of Toxoplasma gondii DNA by PCR following microwave treatment of serum and whole blood. , 2010, The Southeast Asian journal of tropical medicine and public health.

[25]  Weltgesundheitsorganisation World malaria report , 2005 .

[26]  A. Haghighat,et al.  Performance of A 3 MCNP™ for Calculation of 3-D Neutron Flux Distribution in a BWR Core Shroud , 2001 .

[27]  Teun Bousema,et al.  Factors determining the occurrence of submicroscopic malaria infections and their relevance for control , 2012, Nature Communications.

[28]  S. Wanji,et al.  Performance and usefulness of the Hexagon rapid diagnostic test in children with asymptomatic malaria living in the Mount Cameroon region , 2008, Malaria Journal.

[29]  Colin J. Sutherland,et al.  Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda , 2013, The Journal of infectious diseases.

[30]  Nancy Fullman,et al.  The changing epidemiology of malaria elimination: new strategies for new challenges , 2013, The Lancet.