NOWNUNM: Nonlocal Weighted Nuclear Norm Minimization for Sparse-Sampling CT Reconstruction

Computed tomography (CT) image reconstruction using classical total variation (TV)-based methods or its variations inevitably suffers from a blocky effect when the sampling number is low, because of the piecewise assumption. A low-rank based method is an effective way to circumvent this side effect. Normally, a nuclear norm is used to impose the low rank constraint, and its numerical computation depends on the sum of singular values, which are calculated by singular value decomposition. However, as larger singular values mainly deliver the structural information, treating all the singular values equally may lead to imperfect preservation of edges and textures. To deal with this problem, we here propose to reconstruct the CT image by explicitly exploring the nonlocal similarity in the target image with nonlocal weighted nuclear norm minimization. First, a matrix is constructed by grouping nonlocal patches similar to the current patch. Then, the original nuclear norm minimization is replaced by a weighted version, which treats the singular values differently according to their magnitudes. By doing this, we can eliminate noise and streak artifacts without introducing any side effects. The corresponding numerical algorithm is given by an alternating optimization strategy. Experimental results demonstrate that our method outperforms several existing reconstruction methods in both qualitative and quantitative aspects, including filtered back projection, TV, and total generalized variation methods.

[1]  Hu Chen,et al.  LEARN: Learned Experts’ Assessment-Based Reconstruction Network for Sparse-Data CT , 2017, IEEE Transactions on Medical Imaging.

[2]  Steve B. Jiang,et al.  Low-dose 4DCT reconstruction via temporal nonlocal means. , 2010, Medical physics.

[3]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[4]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[5]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[6]  Steve B. Jiang,et al.  Low-dose 4DCT reconstruction via temporal nonlocal means. , 2010, Medical physics.

[7]  Jiliu Zhou,et al.  Few-view image reconstruction with fractional-order total variation. , 2014, Journal of the Optical Society of America. A, Optics, image science, and vision.

[8]  Stanley Osher,et al.  Total variation based image restoration with free local constraints , 1994, Proceedings of 1st International Conference on Image Processing.

[9]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[10]  Peng Bao,et al.  Few‐view CT reconstruction with group‐sparsity regularization , 2018, International journal for numerical methods in biomedical engineering.

[11]  Emmanuel J. Candès,et al.  A Singular Value Thresholding Algorithm for Matrix Completion , 2008, SIAM J. Optim..

[12]  Hu Chen,et al.  Low-dose CT via convolutional neural network. , 2017, Biomedical optics express.

[13]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[14]  Cong Nie,et al.  Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior , 2009, Comput. Medical Imaging Graph..

[15]  Brendt Wohlberg,et al.  Plug-and-Play priors for model based reconstruction , 2013, 2013 IEEE Global Conference on Signal and Information Processing.

[16]  Jean-Michel Morel,et al.  A non-local algorithm for image denoising , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).

[17]  Ge Wang,et al.  Spectral CT Reconstruction With Image Sparsity and Spectral Mean , 2016, IEEE Transactions on Computational Imaging.

[18]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[19]  Natalie N. Braun,et al.  Strategies for reducing radiation dose in CT. , 2009, Radiologic clinics of North America.

[20]  Lei Zhang,et al.  Weighted Nuclear Norm Minimization and Its Applications to Low Level Vision , 2016, International Journal of Computer Vision.

[21]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[22]  Michael Elad,et al.  The Little Engine That Could: Regularization by Denoising (RED) , 2016, SIAM J. Imaging Sci..

[23]  Lei Zhang,et al.  Low-Dose X-ray CT Reconstruction via Dictionary Learning , 2012, IEEE Transactions on Medical Imaging.

[24]  Steve B. Jiang,et al.  Cine Cone Beam CT Reconstruction Using Low-Rank Matrix Factorization: Algorithm and a Proof-of-Principle Study , 2012, IEEE Transactions on Medical Imaging.

[25]  Ge Wang,et al.  Few-view image reconstruction with dual dictionaries , 2012, Physics in medicine and biology.