Disinfection and sterilization in health care facilities: what clinicians need to know.

All invasive procedures involve contact between a medical device or surgical instrument and a patient's sterile tissue or mucous membranes. A major risk of all such procedures is the introduction of pathogenic microbes that could lead to infection. Failure to properly disinfect or sterilize reusable medical equipment carries a risk associated with breach of the host barriers. The level of disinfection or sterilization is dependent on the intended use of the object: critical items (such as surgical instruments, which contact sterile tissue), semicritical items (such as endoscopes, which contact mucous membranes), and noncritical items (such as stethoscopes, which contact only intact skin) require sterilization, high-level disinfection, and low-level disinfection, respectively. Cleaning must always precede high-level disinfection and sterilization. Users must consider the advantages and disadvantages of specific methods when choosing a disinfection or sterilization process. Adherence to these recommendations should improve disinfection and sterilization practices in health care facilities, thereby reducing infections associated with contaminated patient-care items.

[1]  J. Cleveland,et al.  Guidelines for infection control in dental health-care settings--2003. , 2003, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[2]  Fred Silverstein,et al.  Transmission of Infection by Gastrointestinal Endoscopy and Bronchoscopy , 1993, Annals of Internal Medicine.

[3]  Yansheng Zhang,et al.  An outbreak of Mycobacterium chelonae infection following liposuction. , 2002, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[4]  W A Rutala,et al.  Role of Environmental Contamination in the Transmission of Vancomycin-Resistant Enterococci , 1997, Infection Control & Hospital Epidemiology.

[5]  D. Honeybourne,et al.  An audit of bronchoscopy practice in the United Kingdom: a survey of adherence to national guidelines. , 1997, Thorax.

[6]  P. Vanhems,et al.  Outbreaks of infection associated with bronchoscopes. , 2003, The New England journal of medicine.

[7]  W A Rutala,et al.  APIC guideline for selection and use of disinfectants. , 1996, American journal of infection control.

[8]  R. Gaynes,et al.  Biological and chemical terrorism: strategic plan for preparedness and response. , 2000 .

[9]  B. Simmons Anticipatics, handwashing, and handwashing facililties , 1983 .

[10]  S. Block,et al.  Disinfection, sterilization, and preservation , 1977 .

[11]  British Society of Gastroenterology , 1963 .

[12]  Gina Pugliese,et al.  Creutzfeldt-Jakob Disease Recommendations for Disinfection and Sterilization , 2001, Infection Control & Hospital Epidemiology.

[13]  W. Rutala,et al.  Infection control: the role of disinfection and sterilization. , 1999, The Journal of hospital infection.

[14]  Arl Medford,et al.  British Thoracic Society , 2004 .

[15]  D. Taylor Inactivation of prions by physical and chemical means. , 1999, The Journal of hospital infection.

[16]  C. Alvarado,et al.  Multi-society guideline for reprocessing flexible gastrointestinal endoscopes , 2004, Gastrointestinal endoscopy.

[17]  MD Aksel Kruse,et al.  Guidelines on Cleaning and Disinfection in GI Endoscopy , 2000, Endoscopy.

[18]  J. Cleveland,et al.  Guidelines for infection control in dental health-care settings--2003. , 2003, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[19]  E. Bsg Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee , 1998, Gut.

[20]  D. Schembre Infectious complications associated with gastrointestinal endoscopy. , 2000, Gastrointestinal endoscopy clinics of North America.

[21]  W. Rutala,et al.  Disinfection of Endoscopes: Review of New Chemical Sterilants Used for High-Level Disinfection , 1999, Infection Control & Hospital Epidemiology.

[22]  B. Simmons CDC guidelines for the prevention and control of nosocomial infections. Guideline for hospital environmental control. , 1983, American journal of infection control.

[23]  L. Kozak,et al.  Ambulatory and inpatient procedures in the United States, 1996. , 1998, Vital and health statistics. Series 13, Data from the National Health Survey.

[24]  G. Diette,et al.  An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes. , 2003, The New England journal of medicine.

[25]  L. Peterson,et al.  Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying. , 1982, Gastroenterology.

[26]  G. B. Orsi,et al.  Italian National Survey of Digestive Endoscopy Disinfection Procedures. , 1997, Endoscopy.

[27]  Jackson Fw Correction of deficiencies in flexible fiberoptic sigmoidoscope cleaning and disinfection technique in family practice and internal medicine offices. , 1997 .

[28]  G. B. Schaalje,et al.  The Mycobactericidal Efficacy of Ortho-Phthalaldehyde and the Comparative Resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae , 1999, Infection Control & Hospital Epidemiology.

[29]  David J. Weber,et al.  Disinfection and Sterilization In Healthcare Facilities , 2004 .

[30]  R. Wenzel,et al.  Prevention and Control of Nosocomial Infections , 1997 .

[31]  Gregory Aw,et al.  The mycobactericidal efficacy of ortho-phthalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae. , 1999 .

[32]  J. Friend Do smoking parents seek the best advice for their asthmatic children? , 2001, Thorax.

[33]  W A Rutala,et al.  Lessons From Outbreaks Associated With Bronchoscopy , 2001, Infection Control & Hospital Epidemiology.

[34]  D A Henderson,et al.  The looming threat of bioterrorism. , 1999, Science.

[35]  A new method of assessing the penetration of bacteria through fabrics used in the operating theatre. , 1999, The Journal of hospital infection.

[36]  W. Rutala,et al.  Clinical Effectiveness of Low-Temperature Sterilization Technologies , 1998, Infection Control & Hospital Epidemiology.

[37]  Persis Mehta,et al.  Disinfection of medical and surgical materials. , 1971, American journal of hospital pharmacy.

[38]  Garner Js,et al.  CDC Guideline for Handwashing and Hospital Environmental Control, 1985 , 1986, Infection Control.

[39]  R. Wallace,,et al.  Mycobacterium chelonae causing otitis media in an ear-nose-and-throat practice. , 1988, The New England journal of medicine.

[40]  W. Rutala,et al.  Susceptibility of Antibiotic-Susceptible and Antibiotic-Resistant Hospital Bacteria to Disinfectants , 1997, Infection Control & Hospital Epidemiology.

[41]  J. Koval,et al.  Infection control practices across Canada: do dentists follow the recommendations? , 1999, Journal.