Analysis of the field ageing of natural ester transformer dielectrics: Ten years of data

Since 2003 power transformers have been manufactured using natural esters as the insulating dielectric. Before this, these natural ester based dielectrics had been used in factory and distribution type transformers successfully since the mid-1990s. Currently, international standards which would recommend in-service limits for the properties of natural ester are still under development. One reason is that there is insufficient data on which to base these limits. For this study, data from seventeen power transformers containing a natural ester dielectric was gathered, compared, and contrasted with standard mineral oil to evaluate the changes in the fluid expected for normal operation over the first ten years of a power transformer's life. The oldest transformer was ten years old, nearly the same age as the earliest units which use this dielectric. It is hoped that this information will help the industry evaluate the fluid data for their power transformers by understanding what is considered to reflect that of normal operation.

[1]  Ieee Standards Board IEEE guide for acceptance and maintenance of insulating oil in equipment , 1992 .

[2]  Alan Sbravati,et al.  Application of Natural Ester Insulating Liquids in Power Transformers , 2014 .

[3]  D. Martin,et al.  Using a remote system to study the thermal properties of a vegetable oil filled power transformer: How does operation differ from mineral oil , 2011, 2011 IEEE PES Innovative Smart Grid Technologies.

[4]  Michel Duval,et al.  A review of faults detectable by gas-in-oil analysis in transformers , 2002 .

[5]  F. Shahidi,et al.  Bailey's Industrial oil and fat products , 2005 .

[6]  C. Ekanayake,et al.  State of the Art Review On Managing Vegetable Oil Filled Transformers , 2013 .

[7]  M. Duval,et al.  The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformers , 2008, IEEE Electrical Insulation Magazine.

[8]  Daniel Martin,et al.  The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation , 2014, IEEE Electrical Insulation Magazine.

[9]  M. Gordon Bailey's industrial oil and fat products , 1997 .

[10]  C. McShane,et al.  Fire resistant natural ester dielectric fluid and novel insulation system for its use , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[11]  D. Martin,et al.  A Comparative Study of the Chemical Stability of Esters for Use in Large Power Transformers , 2006, 2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[12]  Ian Cotton,et al.  The Use of Natural and Synthetic Ester-Based Transformer Oils in Power Transformers , 2005 .

[13]  Daniel Martin,et al.  Preliminary results for dissolved gas levels in a vegetable oil-filled power transformer , 2010, IEEE Electrical Insulation Magazine.

[14]  D. Martin,et al.  Further studies of a vegetable-oil-filled power transformer , 2011, IEEE Electrical Insulation Magazine.

[15]  I. Cotton,et al.  Dissolved gas analysis of alternative fluids for power transformers , 2007, IEEE Electrical Insulation Magazine.

[16]  Ieee Standards Board IEEE guide for the interpretation of gases generated in oil-immersed transformers , 1992 .

[17]  C.P. McShane,et al.  Aging of paper insulation in natural ester dielectric fluid , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[18]  Susan Redline,et al.  IEEE Guide for Loading Mineral- Oil-Immersed Transformers and Step-Voltage Regulators , 2012 .