Full-Scale Experimental Testing of Retrofitting Techniques in Portuguese “Pombalino” Traditional Timber Frame Walls

Traditional timber frame walls are constructive elements representative of different timber frame buildings, well known as efficient seismic-resistant structures. They were adopted as a seismic-resistant solution in Lisbon’s reconstruction after the 1755 earthquake. To preserve these structures, a better knowledge of their seismic behavior is important and can give indications about possible retrofitting techniques. This article provides a study on possible retrofitting techniques adopting traditional solutions (bolts and steel plates). Static cyclic tests were performed on retrofitted traditional timber frame walls. The experimental results showed the overall good seismic performance of steel plates and the more ductile behavior of bolts retrofitting.

[1]  R. Clough,et al.  Dynamics Of Structures , 1975 .

[2]  Gian Michele Calvi,et al.  In‐plane seismic response of brick masonry walls , 1997 .

[3]  Paulo B. Lourenço,et al.  Experimental Analysis of Reinforced Concrete Block Masonry Walls Subjected to In-Plane Cyclic Loading , 2010 .

[4]  Erol Karacabeyli,et al.  Midply wood shear wall system : Concept and performance in static and cyclic testing , 2006 .

[5]  José S. Machado,et al.  The use of FRP in the strengthening of timber-reinforced masonry load-bearing walls , 2001 .

[6]  Elisa Poletti CHARACTERIZATION OF THE SEISMIC BEHAVIOUR OF TRADITIONAL TIMBER FRAME WALLS , 2013 .

[7]  M. Piazza,et al.  Seismic behavior and retrofitting of joints in traditional timber roof structures , 2002 .

[8]  Miha Tomazevic,et al.  Earthquake-Resistant Design of Masonry Buildings , 1999 .

[9]  H. J. Larsen,et al.  DS/ENV 1995-1-1 NAD National Application Document for Eurocode 5: Design of Timber Structures, Part 1-1: General Rules and Rules for Buildings , 1994 .

[10]  L. G. Jaeger,et al.  Dynamics of structures , 1990 .

[11]  Miha Tomaževič,et al.  Seismic Behavior of Masonry Walls: Experimental Simulation , 1996 .

[12]  Frank Lam,et al.  Lateral Resistance of Wood Shear Walls with Large Sheathing Panels , 1997 .

[13]  Jorge M. Branco Influence of the joints stiffness in the monotonic and cyclic behaviour of traditional timber trusses. Assement of the efficaccy of different strengthenning techniques , 2008 .

[14]  Randolph Langenbach,et al.  From “Opus Craticium” to the “Chicago Frame”: Earthquake-Resistant Traditional Construction , 2007 .

[15]  Adam James Toothman,et al.  Monotonic and Cyclic Performance of Light-Frame Shear Walls with Various Sheathing Materials , 2003 .

[16]  Miroslav Premrov,et al.  Analysis of timber-framed walls coated with CFRP strips strengthened fibre-plaster boards , 2004 .

[17]  Humberto Varum,et al.  Structural rehabilitation of old buildings , 2014 .