현수교 PPWS용 소켓의 내벽 경사각이 소켓의 극한 하중계수에 미치는 영향

Ultimate load factors of PPWS(Prefabricated Parallel Wire Strand) sockets in main cables of suspension bridges are studied with respect to the tapered angles of the inner surface of sockets. After briefly reviewing the current design method, 15 numbers of finite element models of sockets are prepared by varying the number of wires in a strand and the tapered angles. The finite element models are updated by comparing experimental and numerical results, so that the models can reflect the real behavior of sockets. The stress distributions at the first yielding and ultimate states are analyzed by performing the incremental load analysis using ABAQUS. It is concluded that the optimized tapered angle of sockets should be determined at the specific angle between the results of verification equations of the required bonding length and stress resistance length.