Effects of cell concentration and collagen concentration on contraction kinetics and mechanical properties in a bone marrow stromal cell-collagen construct.

A cell-collagen construct is commonly used to investigate the phenomenon of wound healing and to estimate the variables for tissue engineering. The purpose of this study was to assess the effects of cell concentration and collagen concentration on the contraction kinetics and mechanical properties of bone marrow stromal cell (BMSC) seeded collagen lattices. To investigate the effects of both variables on the contraction kinetics, the construct contraction was monitored up to 13 days. Incremental stress- relaxation tests were carried out after a 2-week incubation to obtain the stress-strain profiles, which were subsequently assessed in a quasilinear viscoelastic (QLV) model. During contraction, aligned BMSCs were observed first in the interior portion of the ring, followed by the middle portion and finally in the exterior portion. Constructs seeded with a higher initial cell concentration (higher than 1 x 10(5) cells/mL) or lower initial collagen concentration (lower than 2 mg/mL) exhibited faster contraction, higher ultimate stress, and superior elasticity and reduced relaxation behavior (p < 0.05). The cell-collagen model was successfully used to yield information regarding the initial cell concentration and the initial collagen concentration on contraction kinetics and mechanical behavior, which may have possible application in tissue engineering.

[1]  Robert M. Nerem,et al.  Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro , 2000, Annals of Biomedical Engineering.

[2]  D. Butler,et al.  Effects of cell seeding density and collagen concentration on contraction kinetics of mesenchymal stem cell-seeded collagen constructs. , 2006, Tissue engineering.

[3]  E Bell,et al.  Production of a tissue-like structure by contraction of collagen lattices by human fibroblasts of different proliferative potential in vitro. , 1979, Proceedings of the National Academy of Sciences of the United States of America.

[4]  P. Agache,et al.  A new technique to study the mechanical properties of collagen lattices. , 1992, Journal of biomechanics.

[5]  I. Vesely,et al.  Fabrication of mitral valve chordae by directed collagen gel shrinkage. , 2003, Tissue engineering.

[6]  R T Tranquillo,et al.  An anisotropic biphasic theory of tissue-equivalent mechanics: the interplay among cell traction, fibrillar network deformation, fibril alignment, and cell contact guidance. , 1997, Journal of biomechanical engineering.

[7]  N. Occleston,et al.  Differences in proliferative rate and collagen lattice contraction between endotenon and synovial fibroblasts. , 1998, The Journal of hand surgery.

[8]  R. F. Ker The design of soft collagenous load-bearing tissues. , 1999, The Journal of experimental biology.

[9]  D. Bader,et al.  Influence of external uniaxial cyclic strain on oriented fibroblast-seeded collagen gels. , 2003, Tissue engineering.

[10]  Y. Nomura,et al.  Constraint stress, microstructural characteristics, and enhanced mechanical properties of a special fibroblast-embedded collagen construct. , 2006, Artificial organs.

[11]  Y. Fung Elasticity of soft tissues in simple elongation. , 1967, The American journal of physiology.

[12]  K. An,et al.  Contraction of collagen gels seeded with tendon cells. , 2006, Biorheology.

[13]  H. Ehrlich,et al.  Cell locomotion forces versus cell contraction forces for collagen lattice contraction: an in vitro model of wound contraction. , 1990, Tissue & cell.

[14]  F. Grinnell,et al.  Studies on the mechanism of hydrated collagen gel reorganization by human skin fibroblasts. , 1985, Journal of cell science.

[15]  Natalia Juncosa-Melvin,et al.  Effects of cell-to-collagen ratio in mesenchymal stem cell-seeded implants on tendon repair biomechanics and histology. , 2005, Tissue engineering.

[16]  Kai-Nan An,et al.  Factors related to contraction and mechanical strength of collagen gels seeded with canine endotenon cells. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[17]  J. Wang Mechanobiology of tendon. , 2006, Journal of biomechanics.

[18]  K. An,et al.  Multilayer tendon slices seeded with bone marrow stromal cells: A novel composite for tendon engineering , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  F A Auger,et al.  In vitro construction of a human blood vessel from cultured vascular cells: a morphologic study. , 1993, Journal of vascular surgery.

[20]  Mark Eastwood,et al.  Quantitative analysis of collagen gel contractile forces generated by dermal fibroblasts and the relationship to cell morphology , 1996, Journal of cellular physiology.

[21]  D. Butler,et al.  Tensile stimulation of murine stem cell-collagen sponge constructs increases collagen type I gene expression and linear stiffness. , 2009, Tissue engineering. Part A.

[22]  D L Bader,et al.  A system for monitoring the response of uniaxial strain on cell seeded collagen gels. , 2000, Medical engineering & physics.

[23]  Jeffrey W Holmes,et al.  Creating alignment and anisotropy in engineered heart tissue: role of boundary conditions in a model three-dimensional culture system. , 2003, Tissue engineering.

[24]  Julie Glowacki,et al.  Collagen scaffolds for tissue engineering. , 2008, Biopolymers.