Applicability analysis of sanger & sayles formulas for temperature field of single-row-pipe frozen soil wall
暂无分享,去创建一个
As one of widely used methods in calculating temperature field under single-row-pipe freezing, the Sanger & Sayles Formula yet bears certain error and inaccuracy. In order to investigate the sensibility and applicability of the Sanger & Sayles Formula, numerical calculation is adopted here to check against the formula result with regard to average temperature and thickness of the frozen soil wall under single-row-pipe freezing. The results show that the error is lager for Sanger & Sayles Formula; meanwhile the calculation of Sanger & Sayles Formula is lower than the actual temperature of frozen soil wall, which is unsafe for engineering design.
[1] Xu Shi-liang. Application of ANSYS on the analysis of freezing wall temperature field , 2005 .
[2] F. H. Sayles,et al. Thermal and rheological computations for artificially frozen ground construction , 1979 .
[3] Hisao Izuta,et al. BENDING STRENGTH OF FROZEN SOIL BEAM WITH TEMPERATURE DISTRIBUTION AND CONSIDERATION OF AVERAGE TEMPERATURE EVALUATION METHOD , 2007 .
[4] Yu Feng. Analysis of Trupak and Bakholdin Formulas for Temperature Field of Single-Row-Pipe Frozen Soil Wall , 2008 .