Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields.

The use of high magnetic fields increases the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS) of brain metabolites. Practical limitations arise, however, from susceptibility-induced field distortions, which are increased at higher magnetic field strengths. Solutions to this problem include optimized shimming, provided that active, i.e., electronic, shimming can operate over a sufficient range. To meet our shim requirements, which were an order of magnitude greater than the active shim capacity of our 7T MR system, we developed a combined passive and active shim approach. Simple geometries of ferromagnetic shim elements were derived and numerically optimized to generate a complete set of second-order spherical harmonic shim functions in a modular manner. The major goals of the shim design were maximization of shim field accuracy and ease of practical implementation. The theoretically optimized ferro-shim geometries were mounted on a cylindrical surface and placed inside the magnet bore, surrounding the subject's head and the RF coil. Passive shimming generated very strong shim fields and eliminated the worst of the field distortions, after which the field was further optimized by flexible and highly accurate active shimming. Here, the passive-shimming procedure was first evaluated theoretically, then applied in phantom studies and subsequently validated for in vivo 1H MRS in the macaque visual cortex. No artifacts due to the passive shim setup were observed; adjustments were reproducible between sessions. The modularity and the reduction to two pieces per shim term in this study is an important simplification that makes the method applicable also for passive shimming within single sessions. The feasibility of very strong, flexible and high-quality shimming via a combined approach of passive and active shimming is of great practical relevance for MR imaging and spectroscopy at high field strengths where shim power is limited or where shimming of specific anatomical regions inherently requires strong shim fields.

[1]  Rolf Gruetter,et al.  Fast, noniterative shimming of spatially localized signals. In vivo analysis of the magnetic field along axes , 1992 .

[2]  Mark Jenkinson,et al.  Optimization of static field homogeneity in human brain using diamagnetic passive shims , 2002, Magnetic resonance in medicine.

[3]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[4]  K Ugurbil,et al.  In vivo 1H NMR spectroscopy of the human brain at 7 T , 2001, Magnetic resonance in medicine.

[5]  T. G. Reese,et al.  High-order MR shimming: a simulation study of the effectiveness of competing methods, using an established susceptibility model of the human head , 2005 .

[6]  K. Uğurbil,et al.  Ultrahigh field magnetic resonance imaging and spectroscopy. , 2003, Magnetic resonance imaging.

[7]  H. Wen,et al.  An in vivo automated shimming method taking into account shim current constraints , 1995, Magnetic resonance in medicine.

[8]  R. Cusack,et al.  New Robust 3-D Phase Unwrapping Algorithms: Application to Magnetic Field Mapping and Undistorting Echoplanar Images , 2002, NeuroImage.

[9]  Peter Jezzard,et al.  Utilization of an intra‐oral diamagnetic passive shim in functional MRI of the inferior frontal cortex , 2003, Magnetic resonance in medicine.

[10]  F. Schick,et al.  Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: measurements and numerical simulations. , 2004, Medical physics.

[11]  N. Logothetis,et al.  Functional imaging of the monkey brain , 1999, Nature Neuroscience.

[12]  K O Lim,et al.  Quantitative assessment of improved homogeneity using higher‐order shims for spectroscopic imaging of the brain , 1998, Magnetic resonance in medicine.

[13]  Stuart Crozier,et al.  Determining complicated winding patterns for shim coils using stream functions and the target-field method , 2002 .

[14]  N. Logothetis,et al.  Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 Tesla setup. , 2004, Magnetic resonance imaging.

[15]  Stuart Crozier,et al.  Winding patterns for actively shielded shim coils with asymmetric target-fields , 2003 .

[16]  Josef Pfeuffer,et al.  Region and volume dependencies in spectral line width assessed by 1H 2D MR chemical shift imaging in the monkey brain at 7 T. , 2004, Magnetic resonance imaging.

[17]  S. Huffel,et al.  MR spectroscopy quantitation: a review of time‐domain methods , 2001, NMR in biomedicine.

[18]  K. Sveda,et al.  Shim coils for NMR and MRI solenoid magnets , 1995 .

[19]  Josef Pfeuffer,et al.  High-field localized 1H NMR spectroscopy in the anesthetized and in the awake monkey. , 2004, Magnetic resonance imaging.

[20]  K. Uğurbil,et al.  Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength. , 1998, Journal of magnetic resonance.

[21]  F. Schick,et al.  Numerical modeling of needle tip artifacts in MR gradient echo imaging. , 2004, Medical physics.

[22]  Christian Schwarzbauer,et al.  An evaluation of the use of passive shimming to improve frontal sensitivity in fMRI , 2005, NeuroImage.

[23]  Peter Jezzard,et al.  Requirements for room temperature shimming of the human brain , 2006, Magnetic resonance in medicine.

[24]  T R Brown,et al.  NMR spectral quantitation by principal component analysis , 2001, NMR in biomedicine.

[25]  S Mierisová,et al.  MR spectroscopy quantitation: a review of frequency domain methods , 2001, NMR in biomedicine.

[26]  Jun Shen,et al.  Measurement and automatic correction of high-order B0 inhomogeneity in the rat brain at 11.7 Tesla. , 2004, Magnetic resonance imaging.