Polymeric endovascular strut and lumen detection algorithm for intracoronary optical coherence tomography images

Abstract. Polymeric endovascular implants are the next step in minimally invasive vascular interventions. As an alternative to traditional metallic drug-eluting stents, these often-erodible scaffolds present opportunities and challenges for patients and clinicians. Theoretically, as they resorb and are absorbed over time, they obviate the long-term complications of permanent implants, but in the short-term visualization and therefore positioning is problematic. Polymeric scaffolds can only be fully imaged using optical coherence tomography (OCT) imaging—they are relatively invisible via angiography—and segmentation of polymeric struts in OCT images is performed manually, a laborious and intractable procedure for large datasets. Traditional lumen detection methods using implant struts as boundary limits fail in images with polymeric implants. Therefore, it is necessary to develop an automated method to detect polymeric struts and luminal borders in OCT images; we present such a fully automated algorithm. Accuracy was validated using expert annotations on 1140 OCT images with a positive predictive value of 0.93 for strut detection and an R2 correlation coefficient of 0.94 between detected and expert-annotated lumen areas. The proposed algorithm allows for rapid, accurate, and automated detection of polymeric struts and the luminal border in OCT images.

[1]  Eung Ju Kim,et al.  Coronary stent fracture complicated multiple aneurysms confirmed by 3-dimensional reconstruction of intravascular-optical coherence tomography in a patient treated with open-cell designed drug-eluting stent. , 2014, Circulation.

[2]  Stavros Tsantis,et al.  Automatic quantitative analysis of in-stent restenosis using FD-OCT in vivo intra-arterial imaging. , 2013, Medical physics.

[3]  Adnan Kastrati,et al.  Bioresorbable Vascular Scaffold Technology Benefits From Healthy Skepticism. , 2016, Journal of the American College of Cardiology.

[4]  Dimitrios I. Fotiadis,et al.  3D reconstruction of coronary arteries using Frequency Domain Optical Coherence Tomography images and biplane angiography , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Jacek Bil,et al.  Bioresorbable vascular scaffolds-what does the future bring? , 2016, Journal of thoracic disease.

[6]  Luca Mainardi,et al.  Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method , 2017, PloS one.

[7]  Ciro Indolfi,et al.  Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents. , 2017, Journal of the American College of Cardiology.

[8]  Isam Faik,et al.  Time-dependent 3D simulations of the hemodynamics in a stented coronary artery , 2007, Biomedical materials.

[9]  Michael Joner,et al.  Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients. , 2013, JACC. Cardiovascular interventions.

[10]  Edsger W. Dijkstra,et al.  A note on two problems in connexion with graphs , 1959, Numerische Mathematik.

[11]  Freddy T. Nguyen,et al.  Optical coherence tomography: a review of clinical development from bench to bedside. , 2007, Journal of biomedical optics.

[12]  Jonathan Gillard,et al.  Error propagation in the characterization of atheromatic plaque types based on imaging , 2015, Comput. Methods Programs Biomed..

[13]  Dimitrios I. Fotiadis,et al.  Prediction of Atherosclerotic Plaque Development in an In Vivo Coronary Arterial Segment Based on a Multilevel Modeling Approach , 2017, IEEE Transactions on Biomedical Engineering.

[14]  Bernard Chevalier,et al.  Arterial Remodeling After Bioresorbable Scaffolds and Metallic Stents. , 2017, Journal of the American College of Cardiology.

[15]  Patrick W Serruys,et al.  Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. , 2011, JACC. Cardiovascular interventions.

[16]  Elazer R. Edelman,et al.  Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants , 2016, PloS one.

[17]  Andrew M. Rollins,et al.  Automatic stent detection in intravascular OCT images using bagged decision trees , 2012, Biomedical optics express.

[18]  W. Edwards,et al.  Arterial calcification and not lumen stenosis is highly correlated with atherosclerotic plaque burden in humans: a histologic study of 723 coronary artery segments using nondecalcifying methodology. , 1998, Journal of the American College of Cardiology.

[19]  Elazer R. Edelman,et al.  Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images , 2017, 2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE).

[20]  Fernando Alfonso,et al.  Bioresorbable vascular scaffolds in patients with acute myocardial infarction: a new step forward to optimized reperfusion? , 2016, Journal of thoracic disease.

[21]  Hongki Yoo,et al.  Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage. , 2016, Medical physics.

[22]  J. Fujimoto,et al.  Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. , 2000, Neoplasia.

[23]  A. Rollins,et al.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. , 2009, JACC. Cardiovascular interventions.

[24]  Joanna J Wykrzykowska,et al.  Bioresorbable Scaffolds versus Metallic Stents in Routine PCI. , 2017, The New England journal of medicine.

[25]  Elazer R. Edelman,et al.  Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography , 2018, IEEE Journal of Biomedical and Health Informatics.

[26]  Patrick W Serruys,et al.  Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe: executive summary. , 2015, European heart journal.

[27]  N. Weissman,et al.  Plaque characterization with optical coherence tomography. , 2006, Journal of the American College of Cardiology.

[28]  Kunal N. Chaudhury,et al.  Fast and Provably Accurate Bilateral Filtering , 2016, IEEE Transactions on Image Processing.

[29]  J. M. Bloom Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. , 1998, The New England journal of medicine.

[30]  Fred S Apple,et al.  Universal definition of myocardial infarction. , 2007, Journal of the American College of Cardiology.

[31]  Joanna J Wykrzykowska,et al.  3-Dimensional optical coherence tomography assessment of jailed side branches by bioresorbable vascular scaffolds: a proposal for classification. , 2010, JACC. Cardiovascular interventions.

[32]  Manel Sabaté,et al.  Bioresorbable vascular scaffold implantation in acute coronary syndromes: clinical evidence, tips and tricks , 2015, Postepy w kardiologii interwencyjnej = Advances in interventional cardiology.

[33]  W. Desmet,et al.  Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage , 2012, The International Journal of Cardiovascular Imaging.

[34]  Jacques Ohayon,et al.  Detection of high-risk atherosclerotic plaque: report of the NHLBI Working Group on current status and future directions. , 2012, JACC. Cardiovascular imaging.

[35]  Roberto Manduchi,et al.  Bilateral filtering for gray and color images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[36]  Debabrata Mukherjee Device Thrombosis with Bioresorbable Scaffolds. , 2017, The New England journal of medicine.

[37]  Jeroen Eggermont,et al.  Automatic detection of bioresorbable vascular scaffold struts in intravascular optical coherence tomography pullback runs. , 2014, Biomedical optics express.

[38]  Jeroen Eggermont,et al.  Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography , 2016, The International Journal of Cardiovascular Imaging.

[39]  Alejandro Lucia,et al.  Epidemiology of coronary heart disease and acute coronary syndrome. , 2016, Annals of translational medicine.