Analyzing the Influences of Camera Warm-Up Effects on Image Acquisition

This article presents an investigation of the impact of camera warmup on the image acquisition process and therefore on the accuracy of segmented image features. Based on an experimental study we show that the camera image is shifted to an extent of some tenth of a pixel after camera start-up. The drift correlates with the temperature of the sensor board and stops when the camera reaches its thermal equilibrium. A further study of the observed image flow shows that it originates from a slight displacement of the image sensor due to thermal expansion of the mechanical components of the camera. This sensor displacement can be modeled using standard methods of projective geometry in addition with bi-exponential decay terms to model the temporal dependence. The parameters of the proposed model can be calibrated and then used to compensate warmup effects. Further experimental studies show that our method is applicable to different types of cameras and that the warm-up behaviour is characteristic for a specific camera.

[1]  Glenn Healey,et al.  Radiometric CCD camera calibration and noise estimation , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  Paul R. Cohen,et al.  Camera Calibration with Distortion Models and Accuracy Evaluation , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  T. A. Clarke,et al.  A Frame Grabber Related Error In Subpixel Target Location , 1995 .

[4]  Jin Chen,et al.  Suitability of the Pulnix TM6CN CCD camera for photogrammetric measurement , 1993, Other Conferences.

[5]  Kenichi Kanatani,et al.  Geometric computation for machine vision , 1993 .

[6]  Olivier D. Faugeras,et al.  Automatic calibration and removal of distortion from scenes of structured environments , 1995, Optics & Photonics.

[7]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[8]  Owen Robert Mitchell,et al.  Edge Location to Subpixel Values in Digital Imagery , 1984, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[9]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[10]  H. Beyer Geometric and radiometric analysis of a CCD-camera based photogrammetric close-range system , 1992 .

[11]  Aly A. Farag,et al.  Nonmetric lens distortion calibration: closed-form solutions, robust estimation and model selection , 2003, Proceedings Ninth IEEE International Conference on Computer Vision.

[12]  Gabriel Oliver,et al.  Radiometric calibration of CCD sensors: dark current and fixed pattern noise estimation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[13]  Gene H. Golub,et al.  Matrix computations , 1983 .

[14]  Mark R. Shortis,et al.  Multisensor system self-calibration , 1995, Other Conferences.

[15]  Kam W. Wong Experience with two vision systems , 1990, ISPRS International Conference on Computer Vision and Remote Sensing.

[16]  E. Seto,et al.  Quantifying Head Motion Associated with Motor Tasks Used in fMRI , 2001, NeuroImage.