Control reconfiguration of a boiler-turbine unit after actuator faults

Boiler-turbines are one of the most important parts in power generation plants. The safety problem in such systems has always been a special concern. This paper discusses the application of control reconfig uration by fault-hiding approach for a boiler-turbine unit. In Fault-hiding approach, after occurrence of a fault, nominal controller of the system remains unchanged; instead, a reconfiguration block is designed and placed between nominal controller and faulty plant to modify input signals. Three major faults are assumed to occur in three actuators of the system consisting of fuel flow valve, steam control valve and water flow valve. Faults cause the outputs of the plant to deviate from desired values and in some cases cause instability in the system. Setpoint tracking recovery and optimal performance recovery problems to diminish effects of the faults are investigated. The results of simulations show that the reconfiguration has been successful in both cases and also confirm the applicability of the method for the boiler-turbine unit since the reconfigured closed-loop system has had tolerable properties against faults. Review History: Received: 13 October 2016 Revised: 21 September 2017 Accepted: 4 September 2018 Available Online:14September 2018

[1]  P. Antsaklis,et al.  Stability of the pseudo-inverse method for reconfigurable control systems , 1991 .

[2]  Didier Theilliol,et al.  Fault-tolerant control in dynamic systems: application to a winding machine , 2000 .

[3]  Jan H. Richter,et al.  Reconfigurable Control of Nonlinear Dynamical Systems: A fault-hiding Approach , 2011 .

[4]  Yixin Diao,et al.  Stable fault-tolerant adaptive fuzzy/neural control for a turbine engine , 2001, IEEE Trans. Control. Syst. Technol..

[5]  Jan Lunze,et al.  Control reconfiguration of a thermofluid process by means of a virtual actuator , 2007 .

[6]  Mohammad B. Menhaj,et al.  Control reconfiguration of a boiler-turbine unit after actuator faults , 2016, 2016 4th International Conference on Control, Instrumentation, and Automation (ICCIA).

[7]  Jan M. Maciejowski,et al.  MPC fault-tolerant flight control case study: flight 1862 , 2003 .

[8]  Wolfgang Birk,et al.  Reconfiguration of the Air Control System of a Bark Boiler , 2016, IEEE Transactions on Control Systems Technology.

[9]  Wen Tan,et al.  Linear control of a boiler-turbine unit: analysis and design. , 2008, ISA transactions.

[10]  J. Lunze,et al.  Control reconfiguration demonstrated at a two-degrees-of-freedom helicopter model , 2003, 2003 European Control Conference (ECC).

[11]  Thomas Steffen,et al.  Control Reconfiguration of Dynamical Systems: Linear Approaches and Structural Tests , 2005 .

[12]  E. Yaz Linear Matrix Inequalities In System And Control Theory , 1998, Proceedings of the IEEE.

[13]  M. J. Yazdanpanah,et al.  Reconfigurable control system design using eigenstructure assignment: static, dynamic and robust approaches , 2005 .

[14]  Jämsä-Jounela Fault-tolerant model predictive control ( FTMPC ) for the BioGrate boiler , 2016 .

[15]  Gwo-Ruey Yu,et al.  Propulsion Control of Crippled Aircraft , 1999 .

[16]  Elkhatib Kamal,et al.  Robust Fuzzy Fault-Tolerant Control of Wind Energy Conversion Systems Subject to Sensor Faults , 2012 .

[17]  Paul M. Frank,et al.  Fault diagnostics and fault tolerant control , 1998 .

[18]  Michel Kinnaert,et al.  Diagnosis and Fault-Tolerant Control , 2004, IEEE Transactions on Automatic Control.

[19]  Jakob Stoustrup,et al.  Active and passive fault-tolerant LPV control of wind turbines , 2010, Proceedings of the 2010 American Control Conference.

[20]  Baolin Wu,et al.  Robust adaptive control for attitude tracking of spacecraft with unknown dead-zone , 2015 .

[21]  Johari Halim Shah Osman,et al.  Second-order sliding mode fault-tolerant control of heat recovery steam generator boiler in combined cycle power plants , 2013 .

[22]  Karl Johan Åström,et al.  Dynamic Models for Boiler-Turbine Alternator Units : Data Logs and Parameter Estimation for a 160 MW Unit , 1987 .