Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations

Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. Existing correction methods that use known patient motion obtained from tracking devices either require multi-frame acquisitions, detailed knowledge of the scanner, or specialized reconstruction algorithms. A deconvolution algorithm has been developed that alleviates these drawbacks by using the reconstructed image to estimate the original non-blurred image using maximum likelihood estimation maximization (MLEM) techniques. A high-resolution digital phantom was created by shape-based interpolation of the digital Hoffman brain phantom. Three different sets of 20 movements were applied to the phantom. For each frame of the motion, sinograms with attenuation and three levels of noise were simulated and then reconstructed using filtered backprojection. The average of the 20 frames was considered the motion blurred image, which was restored with the deconvolution algorithm. After correction, contrast increased from a mean of 2.0, 1.8 and 1.4 in the motion blurred images, for the three increasing amounts of movement, to a mean of 2.5, 2.4 and 2.2. Mean error was reduced by an average of 55% with motion correction. In conclusion, deconvolution can be used for correction of motion blur when subject motion is known.

[1]  H. Iida,et al.  Sinogram-based motion correction of PET images using optical motion tracking system and list-mode data acquisition , 2004, IEEE Transactions on Nuclear Science.

[2]  Y. Picard,et al.  Motion correction of PET images using multiple acquisition frames , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[3]  N Raghunath,et al.  Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization , 2009, Physics in medicine and biology.

[4]  R. Wojcik,et al.  A restraint-free small animal SPECT imaging system with motion tracking , 2005, IEEE Transactions on Nuclear Science.

[5]  Pierre Payoux,et al.  Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging. , 2005, Medical physics.

[6]  William H. Richardson,et al.  Bayesian-Based Iterative Method of Image Restoration , 1972 .

[7]  A. Rahmim,et al.  Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach , 2004, IEEE Transactions on Nuclear Science.

[8]  Lutz Tellmann,et al.  Motion artifact reduction on parametric PET images of neuroreceptor binding. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  M. S. Atkins,et al.  Compensation methods for head motion detected during PET imaging , 1996 .

[10]  A. Rahmim,et al.  System Matrix Modeling of Externally Tracked Motion , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[11]  Jayaram K. Udupa,et al.  Shape-based interpolation of multidimensional grey-level images , 1994, Medical Imaging.

[12]  L. Lucy An iterative technique for the rectification of observed distributions , 1974 .

[13]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[14]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[15]  T. Zeffiro,et al.  Head movement in normal subjects during simulated PET brain imaging with and without head restraint. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Uwe Just,et al.  An accurate method for correction of head movement in PET , 2004, IEEE Transactions on Medical Imaging.

[17]  Tae-Seong Kim,et al.  Correction for head movements in multi-slice EPI functional MRI , 1998 .

[18]  Jayaram K. Udupa,et al.  Shape-based interpolation of multidimensional grey-level images , 1996, IEEE Trans. Medical Imaging.

[19]  C. J. Thompson,et al.  Motion correction of PET images using multiple acquisition frames , 1997, IEEE Transactions on Medical Imaging.

[20]  Roger Fulton,et al.  Correction for head movements in positron emission tomography using an optical motion tracking system , 2000 .