Space Radiation Absorbed Dose Distribution in a Human Phantom

Abstract Badhwar, G. D., Atwell, W., Badavi, F. F., Yang, T. C. and Cleghorn, T. F. Space Radiation Absorbed Dose Distribution in a Human Phantom. Radiat. Res. 157, 76–91 (2002). The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65° inclination and ∼380 km altitude) of a fully instrumented Alderson Rando™ phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

[1]  M. Shea,et al.  Calculated Vertical Cutoff Rigidities for the International Space Station During Magnetically Active Times , 1999 .

[2]  Lawrence W. Townsend,et al.  BRYNTRN: A baryon transport model , 1989 .

[3]  G. Reitz,et al.  Active dosimetry on recent space flights. , 1999, Radiation protection dosimetry.

[4]  P. Pihet,et al.  The Homburg Area Neutron Dosemeter HANDI: Characteristics and Optimisation of the Operational Instrument , 1992 .

[5]  L. Braby,et al.  Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model. , 1994, Radiation research.

[6]  S. Nagaoka,et al.  Measurements of LET-distribution, dose equivalent and quality factor with the RRMD-III on the Space Shuttle Missions STS-84, -89 and -91. , 2001, Radiation measurements.

[7]  William J. Burger,et al.  Protons in near earth orbit , 2000 .

[8]  G. Badhwar,et al.  Galactic cosmic radiation environment models , 2001 .

[9]  E. V. Benton,et al.  A study of the radiation environment on board the Space Shuttle flight STS-57. , 1995, Radiation measurements.

[10]  Y. Potapov,et al.  Doses from galactic cosmic ray particles under spacecraft shielding , 1992 .

[11]  T. Cleghorn,et al.  Neutron measurements onboard the space shuttle. , 2001, Radiation measurements.

[12]  F. Cucinotta,et al.  A Comparison of Depth Dependence of Dose and Linear Energy Transfer Spectra in Aluminum and Polyethylene , 2000, Radiation research.

[13]  G. Badhwar,et al.  Validation of the galactic cosmic ray and geomagnetic transmission models. , 2001, Radiation measurements.

[14]  G D Badhwar,et al.  Effective Dose Equivalent on the Ninth Shuttle–Mir Mission (STS-91) , 2000, Radiation research.

[15]  G. Badhwar,et al.  Galactic cosmic radiation model and its applications. , 1996, Advances in space research : the official journal of the Committee on Space Research.

[16]  R. Wilkins,et al.  Alterations in Dose and Lineal Energy Spectra under Different Shieldings in the Los Alamos High-Energy Neutron Field , 2000, Radiation research.

[17]  G. Badhwar,et al.  Internuclear cascade-evaporation model for LET spectra of 200 MeV protons used for parts testing. , 1998, IEEE transactions on nuclear science.

[18]  Norman W. Peddie,et al.  International Geomagnetic Reference Field: the third generation. , 1982 .

[19]  G. Badhwar,et al.  Response of silicon-based linear energy transfer spectrometers: implication for radiation risk assessment in space flights. , 2001, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[20]  E. V. Benton,et al.  TLD efficiency of 7LiF for doses deposited by high-LET particles. , 2000, Radiation measurements.

[21]  J. I. Vette,et al.  AP-8 trapped proton environment for solar maximum and solar minimum. [Computer accessible models , 1976 .

[22]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[23]  J. Wilson,et al.  Interplanetary crew exposure estimates for galactic cosmic rays. , 1992, Radiation research.

[24]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[25]  W. T. Lawrence,et al.  HZETRN: A Heavy Ion/Nucleon Transport Code for Space Radiations , 2003 .

[26]  K. Hardy,et al.  Low earth orbit radiation dose distribution in a phantom head , 1992 .

[27]  J. Wilson,et al.  An analysis of energy deposition in a tissue equivalent proportional counter onboard the space shuttle. , 1999, Radiation measurements.