Physiological Magnetic Stimulation for Arousal of Elderly Car Driver Evaluated With Electro-Encephalogram and Spine Magnetic Field

Reliable evaluation for the arousal effect of magnetized olivine-crushed-stone-crammed vinyl pipe set on an elderly car driver's spine has been carried out measuring a four-points electroencephalogram using driving simulators considering a defined arousal index β/(δ+θ) . A sintered-magnetized-spherical-particles-crammed pipe is developed for realization of periodically pulse distributed surface magnetic field train matching with the magneto-protonics principle. Transition of the magnetic field time series generated from the spine with application of the physiological magnetic stimulation have also been measured using the amorphous wire and CMOS IC based pico-Tesla resolution magneto-impedance sensor, in which existence of alternative areas of cooperativeness and anti-cooperativeness for transition of the arousal index each other along the spine length direction is suggested. A special point on the central spine generating a large bio magnetic field of around 10 nT amplitude as well as corresponding pit of the stomach position was found.

[1]  Shinsuke Nakayama,et al.  Biomagnetic field detection using very high sensitivity magnetoimpedance sensors for medical applications , 2009 .

[2]  T. Uchiyama,et al.  Measurement of Spontaneous Oscillatory Magnetic Field of Guinea-Pig Smooth Muscle Preparation Using Pico-Tesla Resolution Amorphous Wire Magneto-Impedance Sensor , 2011, IEEE Transactions on Magnetics.

[3]  Milli Gauss pursed Magnetic Field Applied Phosphate Buffeted Saline Solution Elevates Intracellular Ca2+ Level and Stimulates Phagocytic Activity of Human Neutrophils , 2002 .

[4]  J. Mathisa,et al.  Excessive daytime sleepiness, crashes and driving capability , 2004 .

[5]  K. Mohri,et al.  Microtesla extremely low frequency magnetic fields may ameliorate hypertension. , 2007, Georgian medical news.

[6]  L. V. Panina,et al.  Recent Advances of Pico-Tesla Resolution Magneto-Impedance Sensor Based on Amorphous Wire CMOS IC MI Sensor , 2012, IEEE Transactions on Magnetics.

[7]  A G Leslie,et al.  Molecular architecture of the rotary motor in ATP synthase. , 1999, Science.

[8]  Henning Stahlberg,et al.  Structural biology: Proton-powered turbine of a plant motor , 2000, Nature.

[9]  M. Finbow,et al.  The vacuolar H+-ATPase: a universal proton pump of eukaryotes. , 1997, The Biochemical journal.

[10]  T. Uchiyama,et al.  Arousal Effect of Physiological Magnetic Stimulation on Elder Person's Spine for Prevention of Drowsiness During Car Driving , 2011, IEEE Transactions on Magnetics.

[11]  Y. Mohri,et al.  Detection of Magnetization of 6 Hz, 10 \upmuT Magnetic Field Applied Water Using PT-MI Sensor , 2010 .

[12]  Jan Pieter Abrahams,et al.  Structure at 2.8 Â resolution of F1-ATPase from bovine heart mitochondria , 1994, Nature.

[13]  R. Zierler,et al.  Duplex sonography of lower extremity arteries. , 1997, Seminars in ultrasound, CT, and MR.

[14]  Masanori Fukushima,et al.  A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study , 2011, Hypertension Research.

[15]  Kaneo Mohri,et al.  Milligauss magnetic field triggering reliable self-organization of water with long-range ordered proton transport through cyclotron resonance , 2003 .

[16]  Kaneo Mohri,et al.  Gradual decreasing characteristics and temperature stability of electric resistivity in water triggered with milligauss AC field , 2002 .