An investigation of dust generation by free falling powders.

To identify the dust generation processes, aluminum oxide powder was dropped as a free falling slug in a test chamber. The effect of the slug's mass, diameter, and drop height upon the aerosol concentration and size distribution was measured with an aerodynamic particle sizer. To differentiate between aerosol generated during the free fall and at the end of the fall, the slug was dropped either onto a flat surface or into a container of water that suppressed dust generation associated with the impact at the end of the fall. Aerosol generation occurred during the slug's free fall as well as at the end of the fall. The falling solid induced an airflow that followed the falling solid to the end of the fall. This induced airflow contained the aerosol generated during the free fall. At the end of the free fall, the induced airflow, combined with air jets created on impact, dispersed the aerosol throughout the test chamber. Additional measurements were made by using "neutral buoyancy" helium-filled bubbles to visualize the airflow in the test chamber. The airflow and ensuing turbulence were sufficient to keep large, inspirable particles suspended throughout the test chamber for periods greater than 10 min. During experimental work, the effect of drop height, mass, and slug diameter upon aerosol generation by a single slug of powder was studied. The results indicated that the manner in which a powder is handled may be as important as material dustiness as measured by a dustiness tester. Aerosol generation can be reduced by minimizing the contact between the falling powder and the air.