A Grid-Voltage-Sensorless Resistive-Active Power Filter With Series LC-Filter

Voltage-sensorless control has been investigated for voltage source inverters (VSIs) for many years due to the reduced system cost and potentially improved system reliability. The VSI-based resistive-active power filters (R-APFs) are now widely used to prevent the harmonic resonance in power distribution network, for which the voltage sensors are needed in order to obtain the current reference. In this paper, a grid-voltage-sensorless control strategy is proposed for the R-APF with series LC-filter. Unlike the traditional resistance emulation method, this proposed control method reshapes the output impedance of the R-APF at the harmonic frequencies, which is independent of the current reference. A fundamental grid-voltage estimation method is also proposed to control the dc-link voltage. The performance of the proposed control method is verified in both simulations and experiments. The results show good accuracy of the emulated resistance and functionality of the dc-link voltage control. With the proposed method, the cost of the R-APF can also be reduced with potentially improved system reliability.

[1]  Zhe Chen,et al.  A Novel Impedance Converter for Harmonic Damping in Loop Power Distribution Systems , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[2]  Tzung-Lin Lee,et al.  Design of a New Cooperative Harmonic Filtering Strategy for Distributed Generation Interface Converters in an Islanding Network , 2007, IEEE Transactions on Power Electronics.

[3]  Germano Lambert-Torres,et al.  Smart Impedance: A New Way to Look at Hybrid Filters , 2016, IEEE Transactions on Smart Grid.

[4]  Hirofumi Akagi,et al.  Implementation and performance of automatic gain adjustment in a shunt-active filter for harmonic damping throughout a power distribution system , 2002 .

[5]  Hirofumi Akagi,et al.  A medium-voltage transformerless AC/DC power conversion system consisting of a diode rectifier and a shunt hybrid filter , 2002 .

[6]  Y. Xing,et al.  Enhanced Frequency-Locked Loop With a Comb Filter Under Adverse Grid Conditions , 2016, IEEE Transactions on Power Electronics.

[7]  Tzung-Lin Lee,et al.  A Dynamic Tuning Method for Distributed Active Filter Systems , 2006, IEEE Transactions on Industry Applications.

[8]  E. J. Currence,et al.  Harmonic resonance at a medium sized industrial plant , 1994 .

[9]  Zhe Chen,et al.  Study of a Novel Equivalent Model and a Long-Feeder Simulator-Based Active Power Filter in a Closed-Loop Distribution Feeder , 2016, IEEE Transactions on Industrial Electronics.

[10]  Frede Blaabjerg,et al.  An Active Damper for Stabilizing Power-Electronics-Based AC Systems , 2014 .

[11]  Tzung-Lin Lee,et al.  An Active Filter With Resonant Current Control to Suppress Harmonic Resonance in a Distribution Power System , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[12]  Dushan Boroyevich,et al.  Parametric study of dead time effect on three phase AC output impedance of Voltage Source Inverter (VSI) , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[13]  H. Akagi,et al.  A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[14]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[15]  Hirofumi Akagi Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems , 1997 .

[16]  Frede Blaabjerg,et al.  A series-ZC-filtered active trap filter for high power voltage source inverter , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[17]  Zhe Chen,et al.  Autonomous control of inverter-interfaced Distributed Generation units for harmonic current filtering and resonance damping in an islanded microgrid , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[18]  Hirofumi Akagi,et al.  A hybrid active filter for damping of harmonic resonance in industrial power systems , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[19]  Zhe Chen,et al.  Site Selection Strategy of Single-Frequency Tuned R-APF for Background Harmonic Voltage Damping in Power Systems , 2013, IEEE Transactions on Power Electronics.

[20]  Frede Blaabjerg,et al.  An Active Trap Filter for Switching Harmonic Attenuation of Low-Pulse-Ratio Inverters , 2017, IEEE Transactions on Power Electronics.

[21]  T. Dionise,et al.  Voltage Distortion on an Electrical Distribution System , 2010, IEEE Industry Applications Magazine.

[22]  Frede Blaabjerg,et al.  A Series-LC-Filtered Active Damper With Grid Disturbance Rejection for AC Power-Electronics-Based Power Systems , 2015, IEEE Transactions on Power Electronics.

[23]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[24]  Hui Li,et al.  Analysis on controller of grid-connected inverter by using virtual circuit , 2015, 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe).

[25]  Tzung-Lin Lee,et al.  Discrete Frequency-Tuning Active Filter to Suppress Harmonic Resonances of Closed-Loop Distribution Power Systems , 2011, IEEE Transactions on Power Electronics.

[26]  K. Wada,et al.  Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[27]  Josep M. Guerrero,et al.  Hybrid Active Filter With Variable Conductance for Harmonic Resonance Suppression in Industrial Power Systems , 2015, IEEE Transactions on Industrial Electronics.