Continuous objective monitoring of alcohol use: twenty-first century measurement using transdermal sensors.

Transdermal alcohol sensors continuously collect reliable and valid data on alcohol consumption in vivo over the course of hours to weeks. Transdermal alcohol readings are highly correlated with breath alcohol measurements, but transdermal alcohol levels lag behind breath alcohol levels by one or more hours owing to the longer time required for alcohol to be expelled through perspiration. By providing objective information about alcohol consumption, transdermal alcohol sensors can validate self-report and provide important information not previously available. In this article, we describe the development and evaluation of currently available transdermal alcohol sensors, present the strengths and limitations of the technology, and give examples of recent research using the sensors.

[1]  R. Swift,et al.  Assessment of Ethanol Consumption with a Wearable, Electronic Ethanol Sensor/Recorder , 1992 .

[2]  Jack Darkes,et al.  The validity of self-reports of alcohol consumption: state of the science and challenges for research. , 2003, Addiction.

[3]  F. D. Del Boca,et al.  Talk is cheap: measuring drinking outcomes in clinical trials. , 2000, Journal of studies on alcohol.

[4]  H. Moss,et al.  Alcohol biomarkers in applied settings: recent advances and future research opportunities. , 2010, Alcoholism, clinical and experimental research.

[5]  M. Phillips,et al.  Evaluation of the Alcopatch, a transdermal dosimeter for monitoring alcohol consumption. , 1995, Alcoholism, clinical and experimental research.

[6]  G A Marlatt,et al.  Verbal report methods in clinical research on alcoholism: response bias and its minimization. , 1987, Journal of studies on alcohol.

[7]  A. Laconti,et al.  Studies on a wearable, electronic, transdermal alcohol sensor. , 1992, Alcoholism, clinical and experimental research.

[8]  J. Baer,et al.  The utility of collateral informant assessment in college alcohol research: results from a longitudinal prevention trial. , 2005, Journal of studies on alcohol.

[9]  K. Preston,et al.  Efficacy and versatility of voucher-based reinforcement in drug abuse treatment. , 1999 .

[10]  S. Maisto,et al.  Using Subject and Collateral Reports to Measure Alcohol Consumption , 1992 .

[11]  L. Sobell,et al.  Self-Report Issues in Alcohol Abuse: State of the Art and Future Directions , 1990 .

[12]  R. Swift,et al.  Transdermal measurement of alcohol consumption. , 1993, Addiction.

[13]  Drinking reports from collateral individuals. , 2003, Addiction.

[14]  James G. Murphy,et al.  Contingency management for alcohol use reduction: a pilot study using a transdermal alcohol sensor. , 2011, Drug and alcohol dependence.

[15]  C. Wang,et al.  Deconvolving an estimate of breath measured blood alcohol concentration from biosensor collected transdermal ethanol data , 2008, Appl. Math. Comput..

[16]  R. Swift,et al.  Direct measurement of alcohol and its metabolites. , 2003, Addiction.

[17]  Paul R Marques,et al.  Field and laboratory alcohol detection with 2 types of transdermal devices. , 2009, Alcoholism, clinical and experimental research.

[18]  R. J. Long,et al.  Validity of transdermal alcohol monitoring: fixed and self-regulated dosing. , 2006, Alcoholism, clinical and experimental research.

[19]  P. Muellerleile,et al.  Collateral reports in the college setting: a meta-analytic integration. , 2005, Alcoholism, clinical and experimental research.