Ridge Extraction From the Time–frequency Representation (TFR) of Signals Based on an Image Processing Approach: Application to the Analysis of Uterine Electromyogram AR TFR

Time-frequency representations (TFRs) of signals are increasingly being used in biomedical research. Analysis of such representations is sometimes difficult, however, and is often reduced to the extraction of ridges, or local energy maxima. In this paper, we describe a new ridge extraction method based on the image processing technique of active contours or snakes. We have tested our method on several synthetic signals and for the analysis of uterine electromyogram or electrohysterogram (EHG) recorded during gestation in monkeys. We have also evaluated a postprocessing algorithm that is especially suited for EHG analysis. Parameters are evaluated on real EHG signals in different gestational periods. The presented method gives good results when applied to synthetic as well as EHG signals. We have been able to obtain smaller ridge extraction errors when compared to two other methods specially developed for EHG. The gradient vector flow (GVF) snake method, or GVF-snake method, appears to be a good ridge extraction tool, which could be used on TFR of mono or multicomponent signals with good results.

[1]  Junaed Sattar Snakes , Shapes and Gradient Vector Flow , 2022 .

[2]  Y. J. Zhang,et al.  A survey on evaluation methods for image segmentation , 1996, Pattern Recognit..

[3]  Jerry L. Prince,et al.  Gradient vector flow: a new external force for snakes , 1997, Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition.

[4]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[5]  Min Wei,et al.  A fast snake model based on non-linear diffusion for medical image segmentation. , 2004, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[6]  C. Marque,et al.  Use of the electrohysterogram signal for characterization of contractions during pregnancy , 1999, IEEE Transactions on Biomedical Engineering.

[7]  Bruno Torrésani,et al.  Characterization of signals by the ridges of their wavelet transforms , 1997, IEEE Trans. Signal Process..

[8]  Catherine Marque,et al.  Uterine EHG Processing for Obstetrical Monitorng , 1986, IEEE Transactions on Biomedical Engineering.

[9]  Aifeng Yao,et al.  An automated image-based technique for tracking sequential surface wave profiles , 2005 .

[10]  C. Marque,et al.  Use of synthetic uterine signals for an optimum choice of time/frequency representation , 1994, Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Leman 17 - Un algorithme rapide d'extraction d'arêtes dans le scalogramme et son utilisation dans la recherche de zones stationnaires , 1998 .

[12]  Catherine Marque,et al.  Analyzing uterine EMG: tracking instantaneous burst frequency , 1995 .

[13]  C. Marque,et al.  Uterine EMG spectral analysis and relationship to mechanical activity in pregnant monkeys , 1996, Medical and Biological Engineering and Computing.

[14]  H. Akaike A new look at the statistical model identification , 1974 .

[15]  C. Marque,et al.  Utilisation des contours actifs ou « snake » pour l'extraction des arêtes de représentations temps-fréquences : Application à l'analyse des contractions utérines , 2005 .

[16]  C Marque,et al.  Uterine electromyography: a critical review. , 1993, American journal of obstetrics and gynecology.

[17]  G. Saade,et al.  Control and assessment of the uterus and cervix during pregnancy and labour. , 1998, Human reproduction update.