Double-Circuit Transmission-Line Fault Location Utilizing Synchronized Current Phasors

Fault location is considered as one of the essential techniques enabling a smart grid. This paper presents a novel fault location approach for double-circuit transmission lines. Various existing algorithms usually require measurements recorded from one or two terminals of the faulted line. However, when such measurements are not available, these methods are not applicable. To fill this gap, this paper proposes a fault location method by harnessing current measurements from one or more branches, which may not be necessarily taken from the faulted section. The currents from multiple branches are synchronized and can be obtained from phasor measurement units installed in the system. The bus impedance matrix technique is exploited to develop the new method. The shunt capacitance of the line is fully considered by utilizing the distributed parameter line model. The network data are assumed to be available. When multiple synchronized current measurements are available, an optimal estimator capable of identifying possible bad measurement data and, thus, further enhancing the fault location is also proposed. Quite accurate results have been achieved based on simulation studies.

[1]  D. J. Lawrence,et al.  Development of an advanced transmission line fault location system. II. Algorithm development and simulation , 1992 .

[2]  S.M. Brahma,et al.  Fault location scheme for a multi-terminal transmission line using synchronized Voltage measurements , 2005, IEEE Transactions on Power Delivery.

[3]  M. S. Sachdev,et al.  A technique for estimating transmission line fault locations from digital impedance relay measurements , 1988 .

[4]  Murari Mohan Saha,et al.  An Accurate Fault Locator with Compensation for Apparent Reactance in the Fault Resistance Resulting from Remote-End Infeed , 1985, IEEE Power Engineering Review.

[5]  Milenko B. Djurić,et al.  Distance protection and fault location utilizing only phase current phasors , 1998 .

[6]  J. Stenzel,et al.  A Practical Fault Location Approach for Double Circuit Transmission Lines Using Single End Data , 2002, IEEE Power Engineering Review.

[7]  S. Elangovan,et al.  Digital distance relaying algorithm for first-zone protection for parallel transmission lines , 1998 .

[8]  I. Zamora,et al.  Best ANN structures for fault location in single-and double-circuit transmission lines , 2005, IEEE Transactions on Power Delivery.

[9]  Gary W. Chang,et al.  Power System Analysis , 1994 .

[10]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[11]  Damir Novosel,et al.  Unsynchronized two-terminal fault location estimation , 1996 .

[12]  Eugeniusz Rosolowski,et al.  Locating faults in parallel transmission lines under availability of complete measurements at one end , 2004 .

[13]  Mladen Kezunovic,et al.  Smart Fault Location for Smart Grids , 2011, IEEE Transactions on Smart Grid.

[14]  Zhang Yao,et al.  Fault location of two-parallel transmission line for non-earth fault using one-terminal data , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[15]  J. A. Jiang,et al.  A New Adaptive PMU-Based Protection Scheme for Transposed/Untransposed Parallel Transmission Lines , 2002, IEEE Power Engineering Review.

[16]  Toshihisa Funabashi,et al.  Digital fault location for parallel double-circuit multi-terminal transmission lines , 2000 .

[17]  J. Suonan,et al.  Parallel transmission lines fault location algorithm based on differential component net , 2005, IEEE Transactions on Power Delivery.

[18]  Christos A Apostolopoulos,et al.  A Novel Algorithm for Locating Faults on Transposed/Untransposed Transmission Lines Without Utilizing Line Parameters , 2010, IEEE Transactions on Power Delivery.

[19]  A. G. Expósito,et al.  Power system state estimation : theory and implementation , 2004 .

[20]  T. Takagi,et al.  Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data , 1982, IEEE Power Engineering Review.

[21]  Soon-Ryul Nam,et al.  A Fault Location Algorithm Based on Circuit Analysis for Untransposed Parallel Transmission Lines , 2008, IEEE Transactions on Power Delivery.

[22]  T. Adu An Accurate Fault Classification Technique for Power System Monitoring Devices , 2002, IEEE Power Engineering Review.

[23]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[24]  Yuan Liao Equivalent PI Circuit for Zero-sequence Networks of Parallel Transmission Lines , 2009 .