Standardisation of near Infrared Spectrometers: Evaluation of Some Common Techniques for Intra- and Inter-Brand Calibration Transfer

Six standardisation methods (direct standardisation, piecewise direct standardisation, robust standardisation, slope and bias and bias only post regression correction and no standardisation or spectral pre-treatment only) were compared for the transfer of whole soybean protein, oil and linolenic acid models. Two Foss Infratec and two Bruins OmegAnalyzerGs instruments were used to evaluate the standardisation methods in intra- and inter-brand scenarios. Each instrument was calibrated on its own calibration set for comparison. Partial least squares was used to develop all models. For each brand, a master was selected and the calibrations developed on it were transferred to the secondary unit of its own network (intra-brand transfer) and to the two units of the other brand (inter-brand transfer). Foss Infratec models were transferable to Bruins OmegAnalyzerG units with a similar or better precision than when all instruments were calibrated on their own calibration sets and vice versa. Optical standardisation methods (techniques that modify spectra of secondary units to match those of the master unit) performed significantly poorer than other methods. Other techniques provided similar results. Pre-processing of the spectra with or without simple treatment of the predictions was sufficient to erase absorption differences and wavelength shifts.

[1]  L. A. Stone,et al.  Computer Aided Design of Experiments , 1969 .

[2]  Steven D. Brown,et al.  Transfer of multivariate calibration models: a review , 2002 .

[3]  P. Corti,et al.  Transfer of calibration in near-infrared reflectance spectrometry , 1998 .

[4]  T. Fearn Standardisation and Calibration Transfer for near Infrared Instruments: A Review , 2001 .

[5]  H. Swierenga,et al.  Comparison of Two Different Approaches toward Model Transferability in NIR Spectroscopy , 1998 .

[6]  J. Shenk,et al.  Calibration Transfer Between near Infrared Reflectance Spectrophotometers , 1985 .

[7]  Nils Bo Büchmann,et al.  The Standardisation of Infratec 1221 near Infrared Transmission Instruments in the Danish Network Used for the Determination of Protein and Moisture in Grains , 1995 .

[8]  Paul Geladi,et al.  Calibration Transfer for Predicting Lake-Water pH from near Infrared Spectra of Lake Sediments , 1999 .

[9]  Luiz E.P. Borges,et al.  Evaluation of Standardisation Methods of near Infrared Calibration Models , 2002 .

[10]  Wulfert,et al.  Correction of temperature-induced spectral variation by continuous piecewise direct standardization , 2000, Analytical chemistry.

[11]  Chris W. Brown,et al.  Calibration transfer from a scanning near-IR spectrophotometer to a FT-near-IR spectrophotometer , 1997 .

[12]  Desire L. Massart,et al.  Calibration transfer across near-infrared spectrometric instruments using Shenk's algorithm: effects of different standardisation samples , 1994 .

[13]  B. Kowalski,et al.  Multivariate instrument standardization , 1991 .

[14]  Onno E. de Noord,et al.  Multivariate calibration standardization , 1994 .

[15]  Jie Lin,et al.  Near-IR Calibration Transfer between Different Temperatures , 1998 .

[16]  Marcelo Nascimento Martins,et al.  A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers. , 2008, Analytica chimica acta.

[17]  Tom Fearn,et al.  Comparing Standard Deviations , 1996 .

[18]  D. Massart,et al.  Standardization of near-infrared spectrometric instruments , 1996 .

[19]  C. Casolino,et al.  Application of standardisation methods to correct the spectral differences induced by a fibre optic probe used for the near-infrared analysis of pharmaceutical tablets. , 1998, Journal of pharmaceutical and biomedical analysis.

[20]  D. Massart,et al.  Standardisation of near-infrared spectrometric instruments: A review , 1996 .