A New Optical-CT Apparatus for 3-D Radiotherapy Dosimetry: Is Free Space Scanning Feasible?

In this paper, we present a new optical computed tomography (Optical-CT) scanner for the verification of the radiation dose schemes delivered in modern radiotherapy applications. The optical-CT scanner is capable of providing rapid relative 3-D dosimetry with high spatial resolution with the use of normoxic N-Vinylpyrrolidone based polymer gel dosimeter. The scanner employs a diffuse uncollimated light illumination beam, a computer controlled motorized rotation stage and a charge-coupled device (CCD) camera. Various test experiments were performed to determine the performance characteristics of the optical-CT apparatus. Attenuation coefficient (¿ ) versus dose calibration data were generated from two calibration experiments using gel containers of two different diameters. All irradiations were performed using a 6 MV linear accelerator. A comparison of the reconstructed images between optical-CT scans using refractive index (RI) matching fluid and corresponding scans performed in free space was demonstrated. The dose readout of a test irradiation model was found to be in good agreement with independent readout performed by MR imaging. The findings presented in this study suggest that polymer dosimeters combined with the new optical-CT scanner constitute a potentially feasible method capable of measuring complex 3-D dose distributions with high resolution and in a wide dose range.

[1]  S. Doran,et al.  A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results , 2001 .

[2]  A. Oppelt,et al.  Multiple‐spin‐echo imaging with a 2D Fourier method , 1986, Magnetic resonance in medicine.

[3]  Jorge Ripoll,et al.  Optical Projection Tomography for In-Vivo Imaging of Drosophila melanogaster , 2008 .

[4]  E Pappas,et al.  An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels , 2007, Physics in medicine and biology.

[5]  J G Wolodzko,et al.  CCD imaging for optical tomography of gel radiation dosimeters. , 1999, Medical physics.

[6]  Simon J. Doran,et al.  Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry , 2006, Physics in medicine and biology.

[7]  Vasilis Ntziachristos,et al.  Volumetric tomography of fluorescent proteins through small animals in vivo. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[8]  M Oldham,et al.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation. , 2007, Medical physics.

[9]  Mark Dewhirst,et al.  Three-dimensional imaging of whole rodent organs using optical computed and emission tomography. , 2007, Journal of biomedical optics.

[10]  M. Oldham,et al.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system. , 2008, Medical physics.

[11]  Ruola Ning,et al.  Pitfalls in point-spread-function measurement of computed tomographic system by microphantom reconstruction , 2005 .

[12]  C Antypas,et al.  Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels. , 2008, Medical physics.

[13]  Tian Liu,et al.  Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner. , 2003, Medical physics.

[14]  Ewald Moser,et al.  The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach. , 2008, Medical physics.

[15]  S L Meeks,et al.  Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries. , 2008, Medical physics.

[16]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[17]  N. Krstajić,et al.  Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry , 2006, Physics in medicine and biology.

[18]  J. Vane,et al.  Optical Projection Tomography as a Tool for 3D Microscopy and Gene Expression Studies , 2002 .

[19]  J. Gore,et al.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner. , 1996, Physics in medicine and biology.

[20]  Mark Oldham,et al.  A practical three-dimensional dosimetry system for radiation therapy. , 2006, Medical physics.

[21]  Nikola Krstajić,et al.  Fast laser scanning optical-CT apparatus for 3D radiation dosimetry , 2007, Physics in medicine and biology.

[22]  Mark Oldham,et al.  An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques. , 2008, Medical physics.

[23]  Vasilis Ntziachristos,et al.  IMAGING SCATTERING MEDIA FROM A DISTANCE: THEORY AND APPLICATIONS OF NONCONTACT OPTICAL TOMOGRAPHY , 2004 .

[24]  L. John Schreiner,et al.  Initial experience with a commercial cone beam optical CT unit for polymer gel dosimetry II: Clinical potential , 2006 .

[25]  E Pappas,et al.  Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison. , 2008, Medical physics.

[26]  J H Siewerdsen,et al.  High resolution gel-dosimetry by optical-CT and MR scanning. , 2001, Medical physics.

[27]  Andrea McNiven,et al.  Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning , 2009, Physics in medicine and biology.

[28]  Mark Oldham,et al.  TU‐C‐224C‐02: A Practical and Accurate 3D Dosimetry System for Radiation Therapy , 2006 .

[29]  C. Wuu,et al.  Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry. , 2006, Medical physics.