Scientific validation of two commercial pressure sensor systems for prosthetic socket fit

The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's FSocket Pressure Measurement System, have been commercially designed for in situ interface pressure measurement over the past decade. Their use is not common in prosthetic practice, perhaps due to questions of cost effectiveness and the difficulties of interpreting the data. Another concern is the use of sensors for pressure measurements in areas of high contour and complex geometries such as the stump. Before these systems can be used in a clinical setting, it is necessary to determine the reliability and accuracy of each system. In order to assess the clinical validity of the Rincoe SFS and FSocket systems, a series of trials was conducted to evaluate different aspects of sensor performance, namely; accuracy, hysteresis, drift and the effect of curvature. The sensors were subjected to tests in flatbed and customdesigned pressure vessels. Overall results indicated an accuracy error for the Rincoe SFS system of 25% (flatbed) and 33% (mould), with a corresponding 15% (flatbed) and 23% (mould) error in hysteresis, and 7% (flatbed) and 11% (mould) drift errors. The FSocket system demonstrated an 8% (flatbed) and 11% (mould) accuracy errors, 42% (flatbed) and 24% (mould) hysteresis errors, and 12% (flatbed) and 33% (mould) drift errors. These findings indicate favourable results for the FSocket Pressure Measurement System compared to the Rincoe Socket Fitting System with respect to its accuracy errors only. Nevertheless, it is the authors’ belief that these systems are adequate in indicating areas of high pressure at the stump socket interface for clinical purposes, but both systems should be used with caution.

[1]  R H Meier,et al.  Stump-socket fit of below-knee prostheses: comparison of three methods of measurement. , 1973, Archives of physical medicine and rehabilitation.

[2]  Y Suzuki,et al.  Sensing stability and dynamic response of the F-Scan in-shoe sensing system: a technical note. , 1998, Journal of rehabilitation research and development.

[3]  Brandstater Me,et al.  Efficacy of three measures to relieve pressure in seated persons with spinal cord injury , 1994 .

[4]  Thomas G. McPoil,et al.  A comparison of two in-shoe plantar pressupe measurement systems , 1995 .

[5]  Freeman Miller,et al.  Using objective measurements from pedobarograph data to assess foot deformities , 1995 .

[6]  A F Mak,et al.  Evaluation of an active seating system for pressure relief. , 1995, Assistive technology.

[7]  E M Burgess,et al.  Clinical measurement of normal and shear stresses on a trans-tibial stump: Characteristics of wave-form shapes during walking , 1993, Prosthetics and orthotics international.

[8]  S W Levy,et al.  Skin problems of the leg amputee. , 1980, Prosthetics and orthotics international.

[9]  James W. Breakey,et al.  Pressures at the Residual Limb-Socket Interface in Transtibial Amputees with Thigh Lacer-Side Joints , 1998 .

[10]  A Polliack,et al.  Sweat analysis following pressure ischaemia in a group of debilitated subjects. , 1997, Journal of rehabilitation research and development.

[11]  C Hughes,et al.  Plantar Pressure Measurements During Ambulation in Weightbearing Conventional Short Leg Casts and Total Contact Casts , 1996, Foot & ankle international.

[12]  Peter R. Cavanagh,et al.  A Method for the Investigation of the Effects of Outsole Modifications in Therapeutic Footwear , 1996, Foot & ankle international.

[13]  J. R. Engsberg,et al.  Quantifying interface pressures in below-knee amputee sockets , 1993 .

[14]  T A Krouskop,et al.  Interface pressures in above-knee sockets. , 1987, Archives of physical medicine and rehabilitation.

[15]  R L Martin,et al.  Plantar Pressure Analysis of Diabetic Rockerbottom Deformity in Total Contact Casts , 1996, Foot & ankle international.

[16]  M Ferguson-Pell,et al.  Prototype development and comparative evaluation of wheelchair pressure mapping system. , 1993, Assistive technology : the official journal of RESNA.

[17]  A W Buis,et al.  Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: Techniques adopted to minimise inaccuracies , 1997, Prosthetics and orthotics international.

[18]  D S Childress,et al.  A review of prosthetic interface stress investigations. , 1996, Journal of rehabilitation research and development.