The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively (p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus (p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) (p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients (p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.

[1]  C. McCollough,et al.  Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose. , 2019, Journal of computer assisted tomography.

[2]  S. Schoenberg,et al.  Combined Static and Dynamic Computed Tomography Angiography of Peripheral Artery Occlusive Disease: Comparison with Magnetic Resonance Angiography , 2018, CardioVascular and Interventional Radiology.

[3]  A. Shetty,et al.  Role of lower extremity run-off CT angiography in the evaluation of acute vascular disease , 2017, Abdominal Radiology.

[4]  Qiuyue Ma,et al.  Assessment of Renal Function and Risk Factors for Chronic Kidney Disease in Patients With Peripheral Arterial Disease , 2017, Angiology.

[5]  Thomas Henzler,et al.  From 3D to 4D: Integration of temporal information into CT angiography studies. , 2015, European journal of radiology.

[6]  L. Norgren,et al.  An update on methods for revascularization and expansion of the TASC lesion classification to include below‐the‐knee arteries: A supplement to the inter‐society consensus for the management of peripheral arterial disease (TASC II): The TASC steering committee* , 2015, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[7]  D. Levin,et al.  Have CT and MR Angiography Replaced Catheter Angiography in Diagnosing Peripheral Arterial Disease? , 2015, Journal of the American College of Radiology : JACR.

[8]  L. Norgren,et al.  An Update on Methods for Revascularization and Expansion of the TASC Lesion Classification to Include Below-the-Knee Arteries: A Supplement to the Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) , 2015, Vascular medicine.

[9]  M. Prokop,et al.  4D-CTA in Neurovascular Disease: A Review , 2015, American Journal of Neuroradiology.

[10]  V. Aboyans,et al.  Epidemiology of peripheral artery disease. , 2015, Circulation research.

[11]  Igor Rudan,et al.  Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis , 2013, The Lancet.

[12]  C. Lücke,et al.  Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection. , 2013, Radiology.

[13]  M. Reiser,et al.  Diagnostic Accuracy of Dynamic Computed Tomographic Angiographic of the Lower Leg in Patients With Critical Limb Ischemia , 2012, Investigative radiology.

[14]  M. Reiser,et al.  Diagnostic value of time-resolved CT angiography for the lower leg , 2010, European Radiology.

[15]  Zhonghua Sun,et al.  Diagnostic accuracy of multislice CT angiography in peripheral arterial disease. , 2006, Journal of vascular and interventional radiology : JVIR.

[16]  S. Wildermuth,et al.  Sixteen-detector row CT angiography for lower-leg arterial occlusive disease: analysis of section width. , 2005, Radiology.

[17]  M. Salvatore,et al.  Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreement. , 2004, European journal of radiology.

[18]  T. Leiner,et al.  Improving the diagnosis of peripheral arterial disease in below-the-knee arteries by adding time-resolved CT scan series to conventional run-off CT angiography. First experience with a 256-slice CT scanner. , 2019, European journal of radiology.

[19]  Yingqiang Guo,et al.  Can multiphase dynamic CT angiography provide a better assessment of aortic dissection compared with the standard triphasic protocol? , 2018, Acta radiologica.

[20]  M. Venermo,et al.  The Feasibility of Angiosome-Targeted Endovascular Treatment in Patients with Critical Limb Ischemia and Foot Ulcer. , 2016, Annals of vascular surgery.