Real-time fault tolerant control of a Reverse Osmosis desalination plant based on a hybrid system approach

Many applications of Reverse Osmosis desalination plants (RO plants) require a fault tolerant system, in particular when human life depends on the availability of the plant for producing fresh water. However, RO plants are little studied from the control engineering point of view: modeling, design of control algorithms and real-time experiments are scarcely reported in the literature. The present work is a study on a real RO plant in order to discover possible faults, to analyze potential methods for Fault-Tolerant Control (FTC) and the real-time experimentation. In order to implement model based control, the plant is identified in several operating points. Model Predictive Control (MPC) is used as control law and a hybrid supervisor is proposed to combine different methods, which perform better for different kind of faults. Satisfactory results are obtained for the real-time operation.

[1]  Youmin Zhang,et al.  Bibliographical review on reconfigurable fault-tolerant control systems , 2003, Annu. Rev. Control..

[2]  Mogens Blanke Fault-tolerant Control Systems , 1999 .

[3]  M. V. Iordache,et al.  Diagnosis and Fault-Tolerant Control , 2007, IEEE Transactions on Automatic Control.

[4]  C. Riverol,et al.  Mathematical Modeling of Perfect Decoupled Control System and Its Application: A Reverse Osmosis Desalination Industrial-Scale Unit , 2005, Journal of automated methods & management in chemistry.

[5]  Albert B. Mindler,et al.  Chapter 2.6 Measurements and control in reverse osmosis desalination , 1986 .

[6]  W. Gill,et al.  REVIEW OF REVERSE OSMOSIS MEMBRANES AND TRANSPORT MODELS , 1981 .

[7]  E. Badreddin,et al.  Optimal control of a reverse osmosis desalination plant using multi-objective optimization , 2006, 2006 IEEE Conference on Computer Aided Control System Design, 2006 IEEE International Conference on Control Applications, 2006 IEEE International Symposium on Intelligent Control.

[8]  Imad Alatiqi,et al.  System identification and control of reverse osmosis desalination , 1989 .

[9]  E. Badreddin,et al.  Dynamic Modeling of a Simple Reverse Osmosis Desalination Plant for Advanced Control Purposes , 2007, 2007 American Control Conference.

[10]  Pradeep B. Deshpande,et al.  Advanced control of a reverse osmosis desalination unit , 1997 .

[11]  P.D. Christofides,et al.  Control of a reverse osmosis desalination process at high recovery , 2008, 2008 American Control Conference.

[12]  Guang-Hong Yang,et al.  Reliable nonlinear control system design by using strictly redundant control elements , 1998 .

[13]  Marcel Staroswiecki Fault tolerant control : The pseudo-inverse method revisited , 2005 .

[14]  Panagiotis D. Christofides,et al.  FAULT-TOLERANT CONTROL OF A REVERSE OSMOSIS DESALINATION PROCESS , 2007 .

[15]  Adrian Gambier,et al.  Real-time performance comparison of fault-tolerant controllers , 2008, 2008 IEEE International Conference on Control Applications.

[16]  A. Gambier,et al.  Real-time control of a hybrid laboratory plant using a receding horizon control strategy , 2004, Proceedings of the 2004 IEEE International Conference on Control Applications, 2004..

[17]  A. Varga A Fault Detection Toolbox for MATLAB , 2006, 2006 IEEE Conference on Computer Aided Control System Design, 2006 IEEE International Conference on Control Applications, 2006 IEEE International Symposium on Intelligent Control.

[18]  Bart De Moor,et al.  N4SID: Subspace algorithms for the identification of combined deterministic-stochastic systems , 1994, Autom..

[19]  Adrian Gambier,et al.  Real-Time Implementation of Fault-Tolerant Control Using Model Predictive Control , 2008 .

[20]  Imad Alatiqi,et al.  Model based control for reverse osmosis desalination processes , 1996 .

[21]  Michel Kinnaert,et al.  Conditioning technique, a general anti-windup and bumpless transfer method , 1987, Autom..

[22]  Hisham Ettouney,et al.  Process control in water desalination industry: an overview☆ , 1999 .

[23]  M. Staroswiecki,et al.  Robust Fault Tolerant Linear Quadratic Control based on Admissible Model Matching , 2006, Proceedings of the 45th IEEE Conference on Decision and Control.

[24]  Abderrahim Abbas,et al.  Modeling an industrial reverse osmosis unit , 1999 .

[25]  Jin Jiang,et al.  Design of reconfigurable control systems using eigenstructure assignments , 1994 .

[26]  M. Abdel-Geliel,et al.  Application of dynamic safety margin in robust fault detection and fault tolerant control , 2006, 2006 IEEE International Conference on Control Applications.

[27]  Carlos Lana,et al.  Desensitized Model Predictive Control Applied to a Structural Benchmark Problem , 2008 .

[28]  Ron J. Patton,et al.  Fault-Tolerant Control: The 1997 Situation , 1997 .

[29]  E. Badreddin,et al.  A reverse osmosis laboratory plant for experimenting with fault-tolerant control , 2009, 2009 American Control Conference.

[30]  Adrian Gambier,et al.  Application of hybrid modeling and control techniques to desalination plants , 2003 .

[31]  Jan M. Maciejowski,et al.  Modelling and predictive control: Enabling technologies for reconfiguration , 1999 .