Design and evaluation of a methodology to perform personalized visual biofeedback for reducing respiratory amplitude in radiation treatment.

A methodology to perform personalized visual biofeedback aimed to the reduction of respiratory amplitude is here proposed. A custom-made software allows to adapt the biofeedback parameters to a patient's respiratory pattern by calculating a limiting range for respiratory amplitude obtained from data acquired during free breathing. The proposed methodology has been tested on ten healthy volunteers and on five lung cancer patients undergoing radiotherapy treatment. The protocol for volunteers consisted of 3 min of data acquisition during the subject's free breathing, 2 min of visual biofeedback within the limits, and 3 min of free breathing. The patients' free breathing was acquired in 3 min and the visual biofeedback performed during all the sessions of the radiotherapy treatment, i.e., an average of eight sessions and an average total treatment time of 2000 s each patient. All the volunteers and three patients of the five found the protocol comfortable. The settlement time needed for considering the limiting range stabilized during free breathing has been calculated as 120 +/- 10 s (p < 0.05). During visual biofeedback the baseline shift was removed and the average respiratory amplitude was reduced by about 40% for all the subjects. The variability of the breathing amplitude remained unaltered during biofeedback. Eight volunteers and three patients remained within the limiting range for more than 90% of the biofeedback period; all subjects remained within the limiting range for more than 80% of the biofeedback period. During the biofeedback period both groups, volunteers and patients, showed a significant increase in breathing frequency which was mostly doubled. Patients with shallow breathing performed comfortably the biofeedback.

[1]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[2]  C. Duvivier,et al.  An inexpensive, MRI compatible device to measure tidal volume from chest-wall circumference , 2007, Physiological measurement.

[3]  E. Yorke,et al.  Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. , 2004, Seminars in radiation oncology.

[4]  Radhe Mohan,et al.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[5]  M. Halliwell,et al.  Ultrasound quantitation of respiratory organ motion in the upper abdomen. , 1994, The British journal of radiology.

[6]  Hiroshi Honda,et al.  Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: system development and feasibility , 2008, Radiation Medicine.

[7]  Steve B Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. , 2003, Physics in medicine and biology.

[8]  Jong Hoon Kim,et al.  Guiding curve based on the normal breathing as monitored by thermocouple for regular breathing. , 2007, Medical physics.

[9]  Steve B. Jiang,et al.  Technical aspects of image-guided respiration-gated radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[10]  O. Wade,et al.  Movements of the thoracic cage and diaphragm in respiration * , 1954, The Journal of physiology.

[11]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[12]  Paul J Keall,et al.  Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform , 2008, Physics in medicine and biology.

[13]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[14]  Radhe Mohan,et al.  SU-FF-T-114: Breath Coaching with Visual Feedback for End-Expiratory Gated Radiotherapy , 2006 .

[15]  S. Webb Motion effects in (intensity modulated) radiation therapy: a review , 2006, Physics in medicine and biology.

[16]  Steve B. Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching , 2006, Physics in medicine and biology.