The accuracy of guided surgery via mucosa-supported stereolithographic surgical templates in the hands of surgeons with little experience.

OBJECTIVES This prospective study analyzed the accuracy of implant placement with mucosa-supported stereolithographic guides, executed by inexperienced surgeons supervised by an experienced colleague. MATERIAL AND METHODS For the accuracy analysis, 75 OsseoSpeed implants™, placed in 17 fully edentulous jaws (16 patients) using a mucosa-supported stereolithographic guide (IMPLANT SAFE Guide, DENTSPLY Implants) and the Facilitate™ protocol, were included. DICOM images of the pre-surgical planning and the post-surgical CBCT were matched using the Mimics(®) software (Materialise Dental). These data were compared with the data (12 jaws, 52 implants) of an experienced surgeon (Vercruyssen et al. Journal of Clinical Periodontology 2014; doi:10.1111/jcpe.12231). RESULTS The global deviation at the coronal and apical point was 0.9 mm (SD 0.5) and 1.1 mm (SD 0.5), respectively. Depth deviations were 0.5 mm (SD 0.5) and 1.1 mm (SD 0.5), respectively, and the angular deviation was 2.8° (SD 1.5°). These deviations were statistically not inferior to the deviations of the experienced surgeon and also within the range of deviations reported by several systematic reviews. CONCLUSION Within the limitations of this study and for the above-mentioned surgical protocol, inexperience of the surgeon had no influence on the accuracy of implant placement in fully edentulous jaws, when all steps needed for the procedure are supervised by experienced dentists.

[1]  R. Jung,et al.  Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry. , 2009, The International journal of oral & maxillofacial implants.

[2]  Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning , 2012, Clinical Oral Investigations.

[3]  G. Obeid,et al.  Implant survival rates for oral and maxillofacial surgery residents: a retrospective clinical review with analysis of resident level of training on implant survival. , 2006, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[4]  G. Romito,et al.  Surgical experience influences 2-stage implant osseointegration. , 2011, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[5]  R Jacobs,et al.  The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. , 2008, Journal of oral rehabilitation.

[6]  H. Avsever,et al.  Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability. , 2013, Clinical implant dentistry and related research.

[7]  I. Turkyilmaz,et al.  Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study. , 2013, The Journal of prosthetic dentistry.

[8]  P. Lambert,et al.  Positive effect of surgical experience with implants on second-stage implant survival. , 1997, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  Marc Quirynen,et al.  Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. , 2013, Clinical oral implants research.

[10]  André Gahleitner,et al.  Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: a prospective radiological study. , 2011, Clinical oral implants research.

[11]  Volkan Arisan Dr. Med. Dent.,et al.  Conventional Multi-Slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for Computer-Assisted Implant Placement. Part I: Relationship of Radiographic Gray Density and Implant Stability , 2012 .

[12]  M. Goldstein,et al.  Minimally invasive flapless implant surgery: a prospective multicenter study. , 2005, Clinical implant dentistry and related research.

[13]  Reinhilde Jacobs,et al.  A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. , 2014, Journal of clinical periodontology.

[14]  D. Kohavi,et al.  Retrospective clinical review of dental implants placed in a university training program. , 2004, The Journal of oral implantology.

[15]  Eric Blanchet,et al.  Effect of flapless surgery on pain experienced in implant placement using an image-guided system. , 2006, The International journal of oral & maxillofacial implants.

[16]  E. Barbato,et al.  How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide? , 2014, International journal of oral and maxillofacial surgery.

[17]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.

[18]  J. D'haese,et al.  Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. , 2012, Clinical implant dentistry and related research.

[19]  E. Machtei,et al.  Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study. , 2009, Clinical oral implants research.

[20]  S. Dandekeri,et al.  Stereolithographic surgical template: a review. , 2013, Journal of clinical and diagnostic research : JCDR.

[21]  Z. Šidák Rectangular Confidence Regions for the Means of Multivariate Normal Distributions , 1967 .

[22]  N. Van Assche,et al.  Tolerance within a surgical guide. , 2010, Clinical oral implants research.

[23]  Ersilia Barbato,et al.  Accuracy of two stereolithographic surgical templates: a retrospective study. , 2013, Clinical implant dentistry and related research.

[24]  M. Trulsson,et al.  Clinical advantages of computer-guided implant placement: a systematic review. , 2012, Clinical oral implants research.

[25]  Reinhilde Jacobs,et al.  Imaging technique selection for the preoperative planning of oral implants: a review of the literature. , 2002, Clinical implant dentistry and related research.

[26]  H. Kyung,et al.  Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise. , 2010, The Angle orthodontist.

[27]  H. Preiskel,et al.  Treatment outcomes in implant therapy: the influence of surgical and prosthodontic experience. , 1995, The International journal of prosthodontics.

[28]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[29]  D. Botticelli,et al.  Computer-guided implant therapy and soft- and hard-tissue aspects. The Third EAO Consensus Conference 2012. , 2012, Clinical oral implants research.

[30]  Hugo De Bruyn,et al.  Effect of smoking habits on accuracy of implant placement using mucosally supported stereolithographic surgical guides. , 2013, Clinical implant dentistry and related research.

[31]  R Jacobs,et al.  Accuracy of computer-aided implant placement. , 2012, Clinical oral implants research.

[32]  J. D'haese,et al.  A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. , 2012, Clinical implant dentistry and related research.