Fault Ride-Through Capability Enhancement of DFIG-Based Wind Turbine With a Flux-Coupling-Type SFCL Employed at Different Locations

Doubly fed induction generators (DFIGs) have attracted a wide interest for wind power generation, but they suffer from high sensitivity to grid disturbances, particularly grid faults. In this paper, a modified flux-coupling-type superconducting fault current limiter (SFCL) is suggested to improve the fault ride-through (FRT) capability of DFIGs. The SFCL's structure and principle is first presented. Then, considering that the SFCL can be installed at a DFIG's different locations, its influence mechanism to the DFIG's FRT capability is analyzed, and some technical discussions on the design of the SFCL are carried out. Furthermore, the simulation model of a 1.5-MW/690-V DFIG integrated with the SFCL is built, and the performance analysis is conducted. From the results, introducing the SFCL can effectively limit the fault currents across the DFIG's stator and rotor sides, and when the stator side is selected as the installation site, the terminal-voltage sag can be also improved, which helps prevent the disconnection of the DFIG from the power grid.

[1]  Hong-Hee Lee,et al.  Performance Enhancement of Stand-Alone DFIG Systems With Control of Rotor and Load Side Converters Using Resonant Controllers , 2012, IEEE Transactions on Industry Applications.

[2]  Luis Marroyo,et al.  Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[3]  Hiroshi Yamaguchi,et al.  Magnetic field and electromagnetic force analysis of 3-phase air-core superconducting power transformer , 2001 .

[4]  Xiong Xiaofu Characteristics of Short-circuit Current of Wind Turbine Driven DFIG and Its Impacts on Grid-connected Distribution Network , 2010 .

[5]  Mohamed Shawky El Moursi,et al.  Voltage Booster Schemes for Fault Ride-Through Enhancement of Variable Speed Wind Turbines , 2013, IEEE Transactions on Sustainable Energy.

[6]  G Pannell,et al.  Analytical Study of Grid-Fault Response of Wind Turbine Doubly Fed Induction Generator , 2010, IEEE Transactions on Energy Conversion.

[7]  J. Morren,et al.  Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator , 2007, IEEE Transactions on Energy Conversion.

[8]  Dong Keun Park,et al.  Development of 220 V/300 A Class Non-Inductive Winding Type Fault Current Limiter Using 2G HTS Wire , 2007, IEEE Transactions on Applied Superconductivity.

[9]  H. Yamaguchi,et al.  Analysis of a 3-phase air-core superconducting power transformer , 1999, IEEE Transactions on Applied Superconductivity.

[10]  W. T. B. de Sousa,et al.  Simulations and Tests of MCP-BSCCO-2212 Superconducting Fault Current Limiters , 2012, IEEE Transactions on Applied Superconductivity.

[11]  F. Grilli,et al.  Quantifying AC Losses in YBCO Coated Conductor Coils , 2007, IEEE Transactions on Applied Superconductivity.

[12]  W Goldacker,et al.  ENSYSTROB—Resistive Fault Current Limiter Based on Coated Conductors for Medium Voltage Application , 2011, IEEE Transactions on Applied Superconductivity.

[13]  P. Student,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG during Voltage Sag and Swell , 2014 .

[14]  Sang-Yun Yun,et al.  Assessment of the Impact of SFCL on Voltage Sags in Power Distribution System , 2011, IEEE Transactions on Applied Superconductivity.

[15]  Ho-Myung Chang,et al.  Two-Stage Cryocooling Design for Hybrid Superconducting Fault Current Limiter , 2010, IEEE Transactions on Applied Superconductivity.

[16]  G. Joos,et al.  A Secondary Voltage Control Strategy for Transmission Level Interconnection of Wind Generation , 2008, IEEE Transactions on Power Electronics.

[17]  Bok-Yeol Seok,et al.  Visualization Study on Boiling of Nitrogen During Quench for Fault Current Limiter Applications , 2006, IEEE Transactions on Applied Superconductivity.

[18]  Li Ren,et al.  SMES Based Excitation System for Doubly-Fed Induction Generator in Wind Power Application , 2011, IEEE Transactions on Applied Superconductivity.

[19]  Li Ren,et al.  Current Limiting Characteristics of a Novel Flux-Coupling Type Superconducting Fault Current Limiter , 2010, IEEE Transactions on Applied Superconductivity.

[20]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[21]  J. Zhang,et al.  AC Loss and Contact Resistance of Resistive Type Fault Current Limiter Using YBCO Coated Conductors , 2012, IEEE Transactions on Applied Superconductivity.

[22]  Y. Xin,et al.  Design, Fabrication, and Operation of the Cryogenic System for a 220 kV/300 MVA Saturated Iron-Core Superconducting Fault Current Limiter , 2014, IEEE Transactions on Applied Superconductivity.

[23]  Li Ren,et al.  Techno-Economic Evaluation of a Novel Flux-Coupling Type Superconducting Fault Current Limiter , 2010, IEEE Transactions on Applied Superconductivity.

[24]  Yuejin Tang,et al.  Influence of a voltage compensation type active superconducting fault current limiter on the transient stability of power system , 2009 .

[25]  A. Polasek,et al.  Comparison Between the Fault Current Limiting Performance of Bi-2212 Bifilar Components and 2G YBCO Coils , 2013, IEEE Transactions on Applied Superconductivity.

[26]  D. A. Mansour,et al.  Improving Fault Ride-Through Capability of DFIG-Based Wind Turbine Using Superconducting Fault Current Limiter , 2013, IEEE Transactions on Applied Superconductivity.

[27]  E. Ruppert,et al.  Fault Current Limiter Using Transformer and Modular Device of YBCO Coated Conductor , 2013, IEEE Transactions on Applied Superconductivity.