Kinetostatic analysis and design optimization of an n-finger underactuated hand exoskeleton

Abstract The concept of underactuation, applied to wearable exoskeletons to empower human users, is very promising, as it permits the designer to limit the number of actuators and consequently the bulk and weight of the device. This paper deals with a scheme of underactuated hand exoskeleton counting generically n fingers. The proposed architecture realizes such a principle at two stages: an intra-finger level and an inter-finger one. Both of them are here analyzed from a kinetostatic point of view; in particular, two alternative transmission mechanisms, relative to the inter-finger stage, are solved, in order to set a comparison. At this point, a design optimization can be performed: in fact, given an objective force profile on the finger phalanges, a number of geometric parameters can be investigated, to let the transmitted forces match the reference ones. Each configuration is numerically evaluated for what concerns the transmitted forces through a properly defined Global Performance Index, while the investigation is conducted through a stochastic algorithm. Finally, an example is provided: a 2-finger exoskeleton is presented and optimized, conceived to help astronauts during Extra Vehicular Activity, an operation that causes hand fatigue and therefore is an ideal field of application for empowering exoskeletons.

[1]  C. D. Gelatt,et al.  Optimization by Simulated Annealing , 1983, Science.

[2]  R.C.V. Loureiro,et al.  Reach & Grasp Therapy: Design and Control of a 9-DOF Robotic Neuro-rehabilitation System , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[3]  Hiroshi Yokoi,et al.  Development of hand rehabilitation system for paralysis patient – universal design using wire-driven mechanism – , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  S.C. Cramer,et al.  A robotic device for hand motor therapy after stroke , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[5]  H. Kawasaki,et al.  Development of a Hand Motion Assist Robot for Rehabilitation Therapy by Patient Self-Motion Control , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[6]  Clément Gosselin,et al.  Underactuated Robotic Hands , 2008, Springer Tracts in Advanced Robotics.

[7]  Kyu-Jin Cho,et al.  Jointless structure and under-actuation mechanism for compact hand exoskeleton , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[8]  J A Main,et al.  Highly mobile space suit material optimization. , 1995, Acta astronautica.

[9]  Nikos G. Tsagarakis,et al.  A novel exoskeleton robotic system for hand rehabilitation - Conceptualization to prototyping , 2014 .

[10]  H de Visser,et al.  Force-directed design of a voluntary closing hand prosthesis. , 2000, Journal of rehabilitation research and development.

[11]  Clément Gosselin,et al.  Analysis of Underactuated Mechanical Grippers , 2001 .

[12]  Paolo Dario,et al.  Design and development of an underactuated prosthetic hand , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[13]  David L. Akin,et al.  The Effects of Extravehicular Activity Gloves on Human Hand Performance , 2001 .

[14]  Vincenzo Parenti Castelli,et al.  State-of-the-Art of Hand Exoskeleton Systems , 2011 .

[15]  Massimo Bergamasco,et al.  Mechanical design of a novel Hand Exoskeleton for accurate force displaying , 2009, 2009 IEEE International Conference on Robotics and Automation.

[16]  Silvia Appendino,et al.  Embedding an Exoskeleton Hand in the Astronaut's EVA Glove: Feasibility and Ideas , 2012 .

[17]  S. Bi,et al.  Classification and type synthesis of 1-DOF remote center of motion mechanisms , 2008 .

[18]  Manuel Ferre,et al.  Efficient human hand kinematics for manipulation tasks , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[19]  A.M. Dollar,et al.  The SDM Hand as a Prosthetic Terminal Device: A Feasibility Study , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[20]  Kotaro Tadano,et al.  Development of grip amplified glove using bi-articular mechanism with pneumatic artificial rubber muscle , 2010, 2010 IEEE International Conference on Robotics and Automation.

[21]  G. Gini,et al.  An EMG-controlled exoskeleton for hand rehabilitation , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[22]  Alessandro Battezzato,et al.  Towards an underactuated finger exoskeleton: An optimization process of a two-phalange device based on kinetostatic analysis , 2014 .

[23]  Soo-Jin Lee,et al.  Current hand exoskeleton technologies for rehabilitation and assistive engineering , 2012 .

[24]  T. Kline,et al.  Control system for pneumatically controlled glove to assist in grasp activities , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[25]  Clément Gosselin,et al.  Force Analysis of Connected Differential Mechanisms: Application to Grasping , 2006, Int. J. Robotics Res..

[26]  Graham Brooker,et al.  Augmented robotic device for EVA hand manoeuvres , 2012 .

[27]  Takashi Maeno,et al.  Underactuated five-finger prosthetic hand inspired by grasping force distribution of humans , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[28]  Francesco Giovacchini,et al.  HANDEXOS: Towards an exoskeleton device for the rehabilitation of the hand , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[29]  Antonio Bicchi,et al.  Hands for dexterous manipulation and robust grasping: a difficult road toward simplicity , 2000, IEEE Trans. Robotics Autom..

[30]  John A. Main,et al.  An anthropomorphic hand exoskeleton to prevent astronaut hand fatigue during extravehicular activities , 1997, IEEE Trans. Syst. Man Cybern. Part A.

[31]  Silvia Appendino,et al.  A new method of measuring the stiffness of astronauts' EVA gloves , 2014 .

[32]  Clément Gosselin,et al.  Kinetostatic analysis of underactuated fingers , 2004, IEEE Transactions on Robotics and Automation.