MRI of the lung gas-space at very low-field using hyperpolarized noble gases.

In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magnetic field (B(0)), making very low-field (VLF) MRI possible; indeed, it is possible to contemplate portable MRI using light-weight solenoids or permanent magnets. This article reports the first in vivo VLF MR images of the lungs in humans and in rats, obtained at a field of only 15 millitesla (150 Gauss).

[1]  Scott D. Swanson,et al.  Distribution and dynamics of laser‐polarized 129Xe magnetization in vivo , 1999 .

[2]  A Macovski,et al.  A readout magnet for prepolarized MRI , 1996, Magnetic resonance in medicine.

[3]  L. Hedlund,et al.  Magnetic resonance angiography with hyperpolarized 129Xe dissolved in a lipid emulsion , 1999, Magnetic resonance in medicine.

[4]  John Clarke,et al.  Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device , 1998 .

[5]  A Macovski,et al.  Novel approaches to low‐cost MRI , 1993, Magnetic resonance in medicine.

[6]  G. Guillot,et al.  Low-field 3He nuclear magnetic resonance in human lungs , 1997 .

[7]  D G Cory,et al.  Low-field MRI of laser polarized noble gas. , 1998, Physical review letters.

[8]  H C Charles,et al.  Cystic fibrosis: combined hyperpolarized 3He-enhanced and conventional proton MR imaging in the lung--preliminary observations. , 1999, Radiology.

[9]  R. Mair,et al.  A system for low field imaging of laser-polarized noble gas. , 1999, Journal of magnetic resonance.

[10]  S. Swanson,et al.  Distribution and dynamics of laser-polarized (129)Xe magnetization in vivo. , 1999, Magnetic resonance in medicine.

[11]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[12]  E E de Lange,et al.  MR imaging and spectroscopy using hyperpolarized 129Xe gas: Preliminary human results , 1997, Magnetic resonance in medicine.

[13]  E. Miron,et al.  Polarization of the nuclear spins of noble-gas atoms by spin exchange with optically pumped alkali-metal atoms , 1984 .

[14]  G H Glover,et al.  Lung parenchyma: magnetic susceptibility in MR imaging. , 1991, Radiology.

[15]  A Potthast,et al.  Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging. , 1996, Radiology.

[16]  R. Walsworth,et al.  Temporal dynamics of hyperpolarized 129Xe resonances in living rats. , 1996, Journal of magnetic resonance. Series B.

[17]  James R. Brookeman,et al.  Lung Air Spaces: MR Imaging Evaluation with , 1999 .

[18]  T A Altes,et al.  Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findings , 2001, Journal of magnetic resonance imaging : JMRI.

[19]  L W Hedlund,et al.  In vivo He-3 MR images of guinea pig lungs. , 1996, Radiology.

[20]  Planinsic Shielding of Low-Frequency Magnetic Interference in Weak-Field MRI by a Single-Layer Cylindrical Coil , 1997, Journal of magnetic resonance.

[21]  N Weiler,et al.  Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI. , 1999, Journal of magnetic resonance.

[22]  B. Agranoff,et al.  Brain MRI with laser‐polarized 129xe , 1997, Magnetic resonance in medicine.

[23]  J. MacFall,et al.  Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients: preliminary results. , 1999, AJR. American journal of roentgenology.

[24]  R. H. Lambert,et al.  Magnetically shielded solenoid with field of high homogeneity , 1975 .

[25]  M. Vannier,et al.  A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy , 1993 .

[26]  W. Happer,et al.  Biological magnetic resonance imaging using laser-polarized 129Xe , 1994, Nature.