Multi-vendor reliability of arterial spin labeling perfusion MRI using a near-identical sequence: Implications for multi-center studies

INTRODUCTION A main obstacle that impedes standardized clinical and research applications of arterial spin labeling (ASL), is the substantial differences between the commercial implementations of ASL from major MRI vendors. In this study, we compare a single identical 2D gradient-echo EPI pseudo-continuous ASL (PCASL) sequence implemented on 3T scanners from three vendors (General Electric Healthcare, Philips Healthcare and Siemens Healthcare) within the same center and with the same subjects. MATERIAL AND METHODS Fourteen healthy volunteers (50% male, age 26.4±4.7years) were scanned twice on each scanner in an interleaved manner within 3h. Because of differences in gradient and coil specifications, two separate studies were performed with slightly different sequence parameters, with one scanner used across both studies for comparison. Reproducibility was evaluated by means of quantitative cerebral blood flow (CBF) agreement and inter-session variation, both on a region-of-interest (ROI) and voxel level. In addition, a qualitative similarity comparison of the CBF maps was performed by three experienced neuro-radiologists. RESULTS There were no CBF differences between vendors in study 1 (p>0.1), but there were CBF differences of 2-19% between vendors in study 2 (p<0.001 in most gray matter ROIs) and 10-22% difference in CBF values obtained with the same vendor between studies (p<0.001 in most gray matter ROIs). The inter-vendor inter-session variation was not significantly larger than the intra-vendor variation in all (p>0.1) but one of the ROIs (p<0.001). CONCLUSION This study demonstrates the possibility to acquire comparable cerebral CBF maps on scanners of different vendors. Small differences in sequence parameters can have a larger effect on the reproducibility of ASL than hardware or software differences between vendors. These results suggest that researchers should strive to employ identical labeling and readout strategies in multi-center ASL studies.

[1]  Marion Smits,et al.  Title Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications : A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia , 2014 .

[2]  Aart J. Nederveen,et al.  Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL) , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[4]  X. Golay,et al.  Vascular disorders: insights from arterial spin labeling. , 2012, Neuroimaging clinics of North America.

[5]  B. Murphy,et al.  Signal-to-noise measures for magnetic resonance imagers. , 1993, Magnetic Resonance Imaging.

[6]  Kim Mouridsen,et al.  The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test–retest study , 2010, NeuroImage.

[7]  Feng Xu,et al.  Estimation of labeling efficiency in pseudocontinuous arterial spin labeling , 2010, Magnetic resonance in medicine.

[8]  Emily Kilroy,et al.  Reliability of two‐dimensional and three‐dimensional pseudo‐continuous arterial spin labeling perfusion MRI in elderly populations: Comparison with 15o‐water positron emission tomography , 2014, Journal of magnetic resonance imaging : JMRI.

[9]  R. Kraft,et al.  Arterial Spin-Labeling in Routine Clinical Practice, Part 2: Hypoperfusion Patterns , 2008, American Journal of Neuroradiology.

[10]  X. Golay,et al.  Perfusion Imaging Using Arterial Spin Labeling , 2004, Topics in magnetic resonance imaging : TMRI.

[11]  John A. Detre,et al.  Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences , 2013, NeuroImage.

[12]  R. Kraft,et al.  Arterial Spin-Labeling in Routine Clinical Practice, Part 3: Hyperperfusion Patterns , 2008, American Journal of Neuroradiology.

[13]  John Ashburner,et al.  A fast diffeomorphic image registration algorithm , 2007, NeuroImage.

[14]  Aart J. Nederveen,et al.  Accuracy and precision of pseudo-continuous arterial spin labeling perfusion during baseline and hypercapnia: A head-to-head comparison with 15O H2O positron emission tomography , 2014, NeuroImage.

[15]  D. Feinberg,et al.  Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements , 2005, Magnetic resonance in medicine.

[16]  Truman R. Brown,et al.  An investigation of statistical power for continuous arterial spin labeling imaging at 1.5 T , 2008, NeuroImage.

[17]  Boris Rubinsky,et al.  Magnetic Resonance Imaging of , 2015 .

[18]  J. Bogousslavsky,et al.  Arterial territories of the human brain , 1998, Neurology.

[19]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[20]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[21]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[22]  Jeroen Hendrikse,et al.  Intra- and Multicenter Reproducibility of Pulsed, Continuous and Pseudo-Continuous Arterial Spin Labeling Methods for Measuring Cerebral Perfusion , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[23]  M. Raichle,et al.  What is the Correct Value for the Brain-Blood Partition Coefficient for Water? , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[24]  J. Detre,et al.  Potentials and Challenges for Arterial Spin Labeling in Pharmacological Magnetic Resonance Imaging , 2011, Journal of Pharmacology and Experimental Therapeutics.

[25]  Christian Barillot,et al.  Template‐based approach for detecting motor task activation‐related hyperperfusion in pulsed ASL data , 2014, Human brain mapping.

[26]  Aart J. Nederveen,et al.  Gray matter contamination in arterial spin labeling white matter perfusion measurements in patients with dementia☆ , 2013, NeuroImage: Clinical.

[27]  Joseph A Maldjian,et al.  Arterial transit time imaging with flow encoding arterial spin tagging (FEAST) , 2003, Magnetic resonance in medicine.

[28]  Yufen Chen,et al.  Test–retest reliability of arterial spin labeling with common labeling strategies , 2011, Journal of magnetic resonance imaging : JMRI.

[29]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[30]  Aart J. Nederveen,et al.  Inter-Vendor Reproducibility of Pseudo-Continuous Arterial Spin Labeling at 3 Tesla , 2014, PloS one.

[31]  Sebastian Kozerke,et al.  Hochkarätige Auszeichnung für RWTH-Radiologin – Univ.-Prof. Dr. med. Christiane Kuhl erhält Gold-Medaille der International Society of Magnetic Resonance in Medicine (ISMRM) , 2015, RöFo.

[32]  Gaohong Wu,et al.  Reliability and precision of pseudo‐continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O‐water PET in elderly subjects at risk for Alzheimer's disease , 2010, NMR in biomedicine.

[33]  Hengyi Rao,et al.  Applications of arterial spin labeled MRI in the brain , 2012, Journal of magnetic resonance imaging : JMRI.